<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Manufacturers Automation</title>
	<atom:link href="http://www.manuauto.com/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.manuauto.com</link>
	<description>Automation and Device Networking - M.A.P.P.</description>
	<lastBuildDate>Mon, 23 Aug 2010 13:02:53 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.8.4</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Moxa NPort 5150 Bench Test</title>
		<link>http://www.manuauto.com/moxa-nport-5150-bench-test/</link>
		<comments>http://www.manuauto.com/moxa-nport-5150-bench-test/#comments</comments>
		<pubDate>Mon, 31 May 2010 21:31:47 +0000</pubDate>
		<dc:creator>brent</dc:creator>
				<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.manuauto.com/?p=3500</guid>
		<description><![CDATA[by Brent Raynor – www.manuauto.com
       
        RS-232 and RS-485 Port Test
         Windows XP Setup

Change the properties of the Local Area Connection. 
Go to Start, Settings, and then Network Connections.  
Select Local Area Connection and then Properties. 
Scroll down the list and select Internet Protocol (TCP/IP).  If IP information is  shown under Use the following IP address, make sure to write it down before proceeding.
Select Use the following [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: center;">by Brent Raynor – <a href="http://www.manuauto.com"><strong><span style="color: #000000;">www.manuauto.com</span></strong></a></p>
<h6 style="text-align: left;"><span style="color: #0000ff;">       <br />
      </span><span style="color: #0000ff;">  RS-232 and RS-485 Port Test</span></h6>
<h6 style="text-align: left;"><span style="color: #0000ff;">         </span><span style="color: #000000;"><span style="text-decoration: underline;">Windows XP Setup</span></span></h6>
<ul>
<li>Change the properties of the <span style="color: #0000ff;">Local Area Connection</span><span style="color: #000000;">.</span> </li>
<li><span style="COLOR: #000000">Go to <span style="color: #0000ff;">Start, Settings</span>, and then <span style="color: #0000ff;">Network Connections</span>.  </span></li>
<li><span style="COLOR: #000000">Select <span style="COLOR: #0000ff"><span style="color: #0000ff;">Local Area Connection</span> </span>and then </span><span style="color: #008000;"><span style="color: #0000ff;">P</span><span style="color: #0000ff;">roperties</span></span><span style="color: #000000;">. </span></li>
<li>Scroll down the list and select <span style="color: #0000ff;">Internet Protocol (TCP/IP)</span><span style="COLOR: #000000">.  If IP information is  shown under <strong>Use the following IP address, </strong>make sure to write it down before proceeding.</span></li>
<li>Select<strong> </strong><span style="color: #006600;">Use the following IP address</span><span style="COLOR: #0000ff"> </span>and enter an <strong>IP address</strong> that is similar to the<strong> </strong><span style="COLOR: #008000"><a href="http://www.moxa.com/product/nport_5150.htm">NPort 5110</a></span>, <span style="COLOR: #ff0000">except </span>for the <strong>last two digits</strong>.</li>
</ul>
<p><span style="color: #000000;"> </span></p>
<p><span style="color: #000000;">         <span style="text-decoration: underline;">Hardware Setup</span></span></p>
<ul>
<li>Connect an ethernet <span style="color: #ff0000;">cross-over </span>cable from the computer to the  <a href="http://www.moxa.com/product/nport_5150.htm">NPort 5150</a><span style="color: #000000;">.</span></li>
</ul>
<p style="text-align: left;"> <strong> </strong></p>
<p style="text-align: left;"><strong>         </strong><span style="text-decoration: underline;">Moxa NPort Management Suite</span></p>
<ul>
<li>
<div style="TEXT-ALIGN: left"><span style="COLOR: #008000"><span style="COLOR: #000000">The first step is to configure the <strong>ethernet side</strong> of the <a href="http://www.moxa.com/product/nport_5150.htm"><span style="COLOR: #008000">NPort </span><span style="color: #008000;">5110</span></a>.  </span></span></div>
</li>
<li>
<div style="TEXT-ALIGN: left"><span style="COLOR: #008000"><span style="COLOR: #000000">Open the NPort Management Suite and select </span></span><span style="COLOR: #008000">Configuration<span style="color: #000000;">.  </span></span></div>
</li>
</ul>
<p style="text-align: center;"> <img class="alignnone size-medium wp-image-3512" title="NPort Administrator Configuration" src="http://www.manuauto.com/wp-content/uploads/2010/05/Pic14-300x236.jpg" alt="NPort Administrator Configuration" width="300" height="236" /></p>
<p style="text-align: center;"><img class="size-medium wp-image-3511   aligncenter" title="NPort Administration Suite Configuration" src="http://www.manuauto.com/wp-content/uploads/2010/05/Pic22-300x239.jpg" alt="NPort Administration Suite Configuration" width="300" height="239" /></p>
<ul>
<li>
<div style="text-align: left;">Select the NPort (MAC Adress) and configure the settings.</div>
</li>
<li>
<div style="text-align: left;">Select <span style="color: #008000;">Network </span>and modify the IP Address, NetMask, and Gateway.</div>
</li>
</ul>
<p style="text-align: center;"><img class="size-medium wp-image-3514 aligncenter" title="NPort Administrator Network Configuration" src="http://www.manuauto.com/wp-content/uploads/2010/05/Pic32-300x237.jpg" alt="NPort Administrator Network Configuration" width="300" height="237" /></p>
<ul>
<li>
<div style="text-align: left;">Select <span style="color: #0000ff;"><span style="color: #008000;">Serial</span></span><span style="color: #000000;">,</span> then select <span style="color: #008000;">Modify</span>, double click the information line and select the <span style="color: #008000;">Settings</span>. </div>
</li>
</ul>
<p style="text-align: center;"><img class="size-medium wp-image-3516   aligncenter" title="NPort Administrator Serial Configuration" src="http://www.manuauto.com/wp-content/uploads/2010/05/pic4-300x238.jpg" alt="NPort Administrator Serial Configuration" width="300" height="238" /></p>
<ul>
<li>
<div style="text-align: left;">Set the baud rate to 9600, 8,N,1, No flow Control, enable FIFO. The    Interface tab is either set to RS-232 or RS-485, 4 wire, depending on what  signal is being tested. </div>
</li>
</ul>
<p style="text-align: center;"><img class="aligncenter" title="NPort Administrator Serial Configuration" src="http://www.manuauto.com/wp-content/uploads/2010/05/pic62-300x237.jpg" alt="NPort Administrator Operating Mode Configuration" width="300" height="237" /></p>
<ul>
<li>Select <span style="color: #008000;">Operation Mode</span>, then select the <span style="color: #008000;">Modify</span> tab, double click the information line and select <span style="color: #008000;">View Settings</span> tab. Set it for <span style="color: #008000;">Real Com Mode.</span><span style="color: #008000;"> </span></li>
<li style="text-align: left;"><span style="color: #008000;"><span style="color: #008000;"><span style="color: #000000;">Select </span><span style="color: #008000;">OK</span> <span style="color: #000000;">and the settings will be updated in the </span><a href="http://www.moxa.com/product/nport_5150.htm">NPort 5110</a>.</span></span></li>
</ul>
<p style="text-align: center;"><img class="size-medium wp-image-3527        aligncenter" title="NPort Administration Operating Mode Configuration" src="http://www.manuauto.com/wp-content/uploads/2010/05/pic8-300x240.jpg" alt="NPort Administration Operating Mode Configuration" width="300" height="240" /></p>
<p style="text-align: center;">   <img title="NPort Administration Reboot Configuration" src="http://www.manuauto.com/wp-content/uploads/2010/05/pic91-300x237.jpg" alt="NPort Administration Reboot Configuration" width="300" height="237" />  </p>
<ul>
<li>
<div style="text-align: left;">The next step is to configure the com port.</div>
</li>
<li>
<div style="text-align: left;">Select <span style="color: #0000ff;"><span style="color: #008000;">COM Mapping</span> </span>and double click the information line to change the serial settings. If there is no information is shown, select <span style="color: #008000;">Add Target.</span></div>
</li>
</ul>
<p style="text-align: center;"><img class="alignnone size-medium wp-image-3546" title="NPort Administration COM Mapping" src="http://www.manuauto.com/wp-content/uploads/2010/05/pic40-300x258.jpg" alt="NPort Administration COM Mapping" width="300" height="258" /></p>
<ul>
<li>
<div style="text-align: left;">Select the NPort required and click <span style="color: #008000;">OK<span style="color: #000000;">.</span></span></div>
</li>
</ul>
<p style="text-align: center;"><img class="alignnone size-medium wp-image-3548" title="NPort Administration Com Mapping" src="http://www.manuauto.com/wp-content/uploads/2010/05/Pic411-300x261.jpg" alt="NPort Administration Com Mapping" width="300" height="261" /></p>
<p style="text-align: center;"><img class="size-medium wp-image-3543 aligncenter" title="NPort Administrator COM Mapping" src="http://www.manuauto.com/wp-content/uploads/2010/05/pic114-300x239.jpg" alt="NPort Administrator COM Mapping" width="300" height="239" /></p>
<ul>
<li>
<div style="text-align: left;">Select <span style="color: #008000;">Basic</span> <span style="color: #008000;">Settings</span> and choose a com port.</div>
</li>
</ul>
<p style="text-align: center;"><img class="alignnone size-medium wp-image-3549" title="NPort Administration COM Mapping " src="http://www.manuauto.com/wp-content/uploads/2010/05/pic42-300x254.jpg" alt="NPort Administration COM Mapping " width="300" height="254" /></p>
<ul>
<li>
<div style="text-align: left;">Select <span style="color: #008000;">Serial Parameters </span>and set for 9600,8,N,1, no flow control.  Click <span style="color: #008000;">OK</span>.</div>
</li>
</ul>
<p style="text-align: center;"><img class="alignnone size-medium wp-image-3558" title="NPort Administrator Serial Com Settings" src="http://www.manuauto.com/wp-content/uploads/2010/05/pic451-300x259.jpg" alt="NPort Administrator Serial Com Settings" width="300" height="259" /></p>
<ul>
<li>
<div style="text-align: left;">Select <span style="color: #008000;">Exit</span>. </div>
</li>
</ul>
<p style="text-align: center;"><img class="alignnone size-medium wp-image-3559" title="NPort Administrator Exit" src="http://www.manuauto.com/wp-content/uploads/2010/05/pic43-300x260.jpg" alt="NPort Administrator Exit" width="300" height="260" /></p>
<h2 style="TEXT-ALIGN: center"><span style="COLOR: #ff0000"><span style="COLOR: #ff0000"> </span></span></h2>
<h2 style="TEXT-ALIGN: center"><span style="COLOR: #ff0000"><span style="color: #ff6600;">Reboot the computer at this point, before doing the loopback test.</span></span></h2>
<h2 style="TEXT-ALIGN: center"><span style="COLOR: #ff0000"><span style="color: #ff6600;"> </span></span></h2>
<h2 style="TEXT-ALIGN: center"><span style="COLOR: #ff0000"><span style="COLOR: #ff0000">HyperTerminal </span></span>Loopback Test</h2>
<p>         <span style="text-decoration: underline;">Test the <strong>RS-232 </strong>communication port</span></p>
<ul>
<li>Jumper <strong>pins 2 </strong>to<strong> 3</strong>on the <span style="COLOR: #008000">Moxa NPort DE-311 </span><span style="COLOR: #000000">DB9 com port.</span></li>
<li><span style="COLOR: #000000">Pin 2 -&gt; TXD       Pin 3 -&gt; RXD  </span></li>
<li>In <strong>Windows XP, </strong><span style="COLOR: #0000ff"><span style="COLOR: #000000">go to <span style="COLOR: #0000ff">start</span>, <span style="COLOR: #0000ff">programs</span></span>, accessories<span style="COLOR: #000000">, </span>communications<span style="COLOR: #000000">, and select <span style="COLOR: #ff0000">HyperTerminal</span>.</span></span></li>
<li>Type a name for this project.          </li>
</ul>
<p style="text-align: center;"><img class="alignnone size-full wp-image-3578" title="NPort 5150 with RS-232 Test Jumper" src="http://www.manuauto.com/wp-content/uploads/2010/05/RS232-Revised10.JPG" alt="NPort 5150 with RS-232 Test Jumper" width="177" height="256" /></p>
<p style="text-align: center;">          </p>
<ul>
<li>
<div style="text-align: left;"> Select the <strong>com port</strong> that was assigned in <span style="COLOR: #008000">Real </span><span style="color: #008000;">COM Installer<span style="color: #000000;">.</span></span></div>
</li>
</ul>
<p style="text-align: center;"><img title="pic5a2" src="http://www.manuauto.com/wp-content/uploads/2009/04/pic5a2-300x188.jpg" alt="pic5a2" width="300" height="188" /></p>
<ul>
<li>
<div style="text-align: left;">Com port settings are 9600, 8, N, 1, None.  Click <strong>OK</strong>.</div>
</li>
</ul>
<p style="text-align: right;">                                       <span style="COLOR: #ff0000"> <a href="http://www.manuauto.com/wp-content/uploads/2009/02/pic661.jpg"></a></span></p>
<p style="TEXT-ALIGN: center"><img title="9600-baud" src="http://www.manuauto.com/wp-content/uploads/2009/04/9600-baud-300x217.jpg" alt="9600-baud" width="300" height="217" /></p>
<ul>
<li>
<div style="text-align: left;">Type a message and it will appear on the <span style="COLOR: #ff0000">HyperTerminal</span> screen. This confirms the <strong>RS-232</strong> communication port works accordingly. Test this procedure by removing the jumper.  As you type, the characters will <span style="COLOR: #ff0000">not </span>appear on the <span style="COLOR: #ff0000">HyperTerminal</span> screen.   </div>
</li>
</ul>
<p style="text-align: center;">                                          <a href="http://www.manuauto.com/wp-content/uploads/2009/02/pic71.jpg"><img class="aligncenter" title="pic71" src="http://www.manuauto.com/wp-content/uploads/2009/02/pic71-300x170.jpg" alt="" width="300" height="170" /></a><a href="http://www.manuauto.com/wp-content/uploads/2009/02/pic7.jpg"></a></p>
<p style="TEXT-ALIGN: left">     </p>
<p style="TEXT-ALIGN: left">         <span style="text-decoration: underline;">Test the <span style="text-decoration: underline;"><strong>RS-422/485 </strong>communication port</span></span></p>
<ul style="TEXT-ALIGN: left">
<li>Jumper <strong>pins 2 </strong>to<strong> 3 </strong>and<strong> 1 </strong>to <strong>4 </strong>on the <span style="COLOR: #008000">Moxa NPort DE-311 </span><span style="COLOR: #000000">DB9 com port </span><span style="COLOR: #000000">using two paperclips.</span></li>
<li>Pin 2 -&gt; RXD+(B)       Pin 3 -&gt; TXD+(B) </li>
<li>Pin 1 -&gt; RXD-(A)        Pin 4 -&gt; TXD-(A) </li>
<li><span style="COLOR: #ff0000"><span style="COLOR: #ff0000"><span style="COLOR: #000000">Repeat the </span><span style="text-decoration: underline;">HyperTerminal </span></span></span><span style="text-decoration: underline;">Loopback Test.</span></li>
</ul>
<p style="text-align: center;"> </p>
<p style="TEXT-ALIGN: center">At<strong> Manufacturers Automation Inc</strong>., we are dedicated to customer service and want to make your experience with <span style="color: #006600;"><strong>Moxa</strong> </span>a pleasant one.</p>
<p style="TEXT-ALIGN: center">© Copyright 2010, Manufacturers Automation Inc., <a href="http://www.manuauto.com/"><strong><span style="COLOR: #666666">www.manuauto.com</span></strong></a></p>
<p style="TEXT-ALIGN: center"> </p>
<address style="TEXT-ALIGN: center">Manufacturers Automation Inc.</address>
<address style="TEXT-ALIGN: center">1600 King Street North</address>
<address style="TEXT-ALIGN: center">P.O. Box 602</address>
<address style="TEXT-ALIGN: center">St. Jacobs, ON N0B 2NO</address>
<address style="TEXT-ALIGN: center">800-387-6268 Tel.      519-664-3300 Tel. </address>
<address style="TEXT-ALIGN: center">519-664-1600 Fax.</address>
]]></content:encoded>
			<wfw:commentRss>http://www.manuauto.com/moxa-nport-5150-bench-test/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>StreetSmart 17X Ethernet Port Configuration</title>
		<link>http://www.manuauto.com/streetsmart-17x-ethernet-port-configuration/</link>
		<comments>http://www.manuauto.com/streetsmart-17x-ethernet-port-configuration/#comments</comments>
		<pubDate>Thu, 27 May 2010 16:00:49 +0000</pubDate>
		<dc:creator>brent</dc:creator>
				<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.manuauto.com/?p=3415</guid>
		<description><![CDATA[by Brent Raynor – www.manuauto.com
 
How to configure the StreetSmart ethernet port
 
 


Connect an RS232 cable to COM O of the Adaptive StreetSmart controller board



 


Open the Diagnostic program in the AlphaNet software


Configure the Serial Settings, 9600, 8, N, 1  and select OK


    
 


Select Set Custom Commands   



 

Select Command 3
Select Open Ini File 



When entering the IP address or subnet mask make sure to enter three numbers before each [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: center;">by Brent Raynor – <a href="http://www.manuauto.com/?PHPSESSID=bf3390c105edfecee3fc35aedbd2eea6"><strong><span style="COLOR: #000000">www.manuauto.com</span></strong></a></p>
<p style="text-align: center;"> </p>
<h6 style="text-align: center;"><span style="color: #0000ff;">How to configure the StreetSmart ethernet port</span></h6>
<p style="text-align: center;"><img class="alignnone size-medium wp-image-3494" title="StreetSmart Ethernet Port" src="http://www.manuauto.com/wp-content/uploads/2010/05/Ethernet-Port-300x295.jpg" alt="StreetSmart Ethernet Port" width="300" height="295" /> </p>
<p style="text-align: center;"> </p>
<ul>
<li>
<div style="text-align: left;">Connect an RS232 cable to <span style="color: #0000ff;">COM O <span style="color: #000000;">of the </span></span>Adaptive StreetSmart controller board</div>
<p style="text-align: center;"><img class="size-medium wp-image-3425      aligncenter" title="StreetSmart 17X Controller Board Picture" src="http://www.manuauto.com/wp-content/uploads/2010/05/StreetSmart-17X-Pics-016-Revised3-294x300.jpg" alt="StreetSmart 17X Pics 016 Revised" width="250" height="360" /></p>
</li>
</ul>
<p style="text-align: left;"> </p>
<ul>
<li>
<div style="text-align: left;">Open the <span style="color: #0000ff;">Diagnostic</span><strong> </strong>program in the <span style="color: #0000ff;">AlphaNet <span style="color: #000000;">software</span></span></div>
</li>
<li>
<div style="text-align: left;">Configure the <span style="color: #0000ff;">Serial Settings</span>, 9600, 8, N, 1  and select OK</div>
</li>
</ul>
<p style="text-align: center;">    <img class="size-medium wp-image-3434  aligncenter" title="AlphaNet Diagnostic Serial Settings" src="http://www.manuauto.com/wp-content/uploads/2010/05/Pic12-300x231.jpg" alt="AlphaNet Diagnostic Serial Settings" width="300" height="230" /></p>
<p style="text-align: center;"> </p>
<ul>
<li>
<div style="text-align: left;">Select <span style="color: #0000ff;">Set Custom Commands</span>   </div>
</li>
</ul>
<p style="text-align: center;"><img class="aligncenter" title="AlphaNet Custom Commands" src="http://www.manuauto.com/wp-content/uploads/2010/05/Pic21-300x230.jpg" alt="AlphaNet Custom Commands" width="300" height="231" /></p>
<p> </p>
<ul>
<li>Select <span style="color: #0000ff;">Command 3</span></li>
<li>Select <span style="color: #0000ff;">Open Ini File</span><strong> </strong></li>
</ul>
<p style="text-align: center;"><img class="aligncenter" title="AlphaNet Custom Commands" src="http://www.manuauto.com/wp-content/uploads/2010/05/Pic31-300x230.jpg" alt="AlphaNet Custom Commands" width="300" height="230" /></p>
<ul>
<p style="text-align: left;"><span style="color: #ff0000;">When entering the IP address or subnet mask make sure to enter<strong> three numbers</strong> before each dot.      ie.    010.011.011.254</span></p>
<li><span style="color: #000000;">Input the IP address and Subnet Mask</span></li>
<li>Type under <span style="color: #0000ff;">Command 3 </span> in <span style="color: #ff6600;">capital letters</span></li>
<li>_01Z00_02EUi<span style="color: #ff0000;">010.001.001.060</span>_04</li>
<li>Type under <span style="color: #0000ff;">Command 4 </span> in <span style="color: #ff6600;">capital  letters</span> </li>
<li>_01Z00_02EUs<span style="color: #ff0000;">255.255.255.000</span>_04</li>
<li>Save and close</li>
</ul>
<p style="text-align: center;"><img class="size-medium wp-image-3445 aligncenter" title="AlphaNet Diagnostic INI File" src="http://www.manuauto.com/wp-content/uploads/2010/05/pic5-300x207.jpg" alt="AlphaNet Diagnostic INI File" width="300" height="207" /></p>
<p> </p>
<ul>
<li>Select <span style="color: #0000ff;">Command 3</span> and the button will turn on.</li>
<li>Click on <span style="color: #0000ff;">Refresh</span> and the IP address will update.</li>
<li>Select <span style="color: #0000ff;">Send </span><strong> </strong>(takes 30 seconds to update the EPROM)</li>
</ul>
<p style="text-align: center;"><img class="size-full wp-image-3448  aligncenter" title="AlphaNet Send Custom Commands" src="http://www.manuauto.com/wp-content/uploads/2010/05/pic6.jpg" alt="AlphaNet Send Custom Commands" width="300" height="207" /></p>
<p> </p>
<ul>
<li>Confirm the IP address in StreetSmart display by typing _01Z00_02FUi_04             </li>
<li>Select <span style="color: #0000ff;">Enter Your Own Command Text</span></li>
<li>and after 30 seconds the changes will appear in the <span style="color: #0000ff;">Results </span>box</li>
</ul>
<p style="text-align: center;"><img class="size-full wp-image-3449 aligncenter" title="AlphaNet Custom Commands" src="http://www.manuauto.com/wp-content/uploads/2010/05/Pic7.jpg" alt="AlphaNet Custom Commands" width="300" height="207" /></p>
<p> </p>
<ul>
<li><span style="color: #ff6600;">Recycle power </span>on the StreetSmart led display and the new IP address will appear on the diagnostic startup of the display.</li>
</ul>
<p> </p>
<p style="text-align: center;">At<strong> Manufacturers Automation Inc</strong>., we are dedicated to customer service and want to make your experience with Adaptive a pleasant one.</p>
<p style="TEXT-ALIGN: center">© Copyright 2010, Manufacturers Automation Inc., <a href="http://www.manuauto.com/"><strong><span style="COLOR: #666666">www.manuauto.com</span></strong></a></p>
<p style="TEXT-ALIGN: center"> </p>
<address style="TEXT-ALIGN: center">Manufacturers Automation Inc.</address>
<address style="TEXT-ALIGN: center">1600 King Street North</address>
<address style="TEXT-ALIGN: center">P.O. Box 602</address>
<address style="TEXT-ALIGN: center">St. Jacobs, ON N0B 2NO</address>
<address style="TEXT-ALIGN: center">800-387-6268 Tel.      519-664-3300 Tel. </address>
<address style="TEXT-ALIGN: center">519-664-1600 Fax.</address>
]]></content:encoded>
			<wfw:commentRss>http://www.manuauto.com/streetsmart-17x-ethernet-port-configuration/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Wireless Site Survey &#8211; Model 1650 WiFi</title>
		<link>http://www.manuauto.com/adaptive-wireless-site-survey-model-1650-wifi/</link>
		<comments>http://www.manuauto.com/adaptive-wireless-site-survey-model-1650-wifi/#comments</comments>
		<pubDate>Thu, 11 Mar 2010 19:40:30 +0000</pubDate>
		<dc:creator>brent</dc:creator>
				<category><![CDATA[News]]></category>
		<category><![CDATA[access point and bridge]]></category>
		<category><![CDATA[Adaptive EzView led display communications]]></category>
		<category><![CDATA[Adaptive Site Survey]]></category>
		<category><![CDATA[Model 1650 WiFi]]></category>
		<category><![CDATA[Wireless signal strength]]></category>

		<guid isPermaLink="false">http://www.manuauto.com/?p=3285</guid>
		<description><![CDATA[
by Brent Raynor – www.manuauto.com
  
      Recommended Procedure For A Sight Survey And Install

Access point (receiver) 192.168.1.232
Bridge  (transmitter) 192.168.1.231
Clear line of sight required, free of obstructions (ie. trees).
Maximum distance between Acesss point and Bridge is 300 feet. 


 
       Changing your computer&#8217;s IP address to communicate with the Access point (sign side)

Change the properties of the Local Area Connection.
Go to Start, Settings, and then Network [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: center;"><a href="http://www.adaptivedisplays.com/Documentation/questions.php?questionid=314"></a></p>
<p style="text-align: center;"><span style="color: #0000ff;"><span style="text-decoration: underline;"><span style="color: #000000;">by Brent Raynor – </span><a href="http://www.manuauto.com/?PHPSESSID=bf3390c105edfecee3fc35aedbd2eea6"><strong><span style="color: #000000;">www.manuauto.com</span></strong></a></span></span></p>
<p style="text-align: center;"><span style="color: #000000;">  </span></p>
<p style="text-align: center;"><span style="color: #000000;">      <span style="text-decoration: underline;">R</span></span><span style="text-decoration: underline;">ecommended Procedure For A Sight Survey And Install</span></p>
<ul>
<li><span style="color: #ff0000;"><span style="color: #0000ff;">Access point <span style="color: #000000;">(receiver) </span></span></span><span style="color: #000000;"><span style="color: #000000;">1</span>92</span><span style="color: #000000;">.</span>168.1.232</li>
<li><span style="color: #0000ff;"><span style="color: #ff0000;"><span style="color: #0000ff;">Bridge </span></span><span style="color: #0000ff;"> <span style="color: #000000;">(transmitter) </span></span></span><span style="color: #000000;">1</span>92.168.1.231</li>
<li>Clear line of sight required, free of obstructions (ie. trees).</li>
<li>Maximum distance between Acesss point and Bridge is 300 feet. </li>
</ul>
<p style="text-align: center;"><img class="aligncenter size-full wp-image-3370" title="1650" src="http://www.manuauto.com/wp-content/uploads/2010/03/16509.jpg" alt="1650" width="884" height="393" /></p>
<p> </p>
<p>       <span style="text-decoration: underline;">Changing your computer&#8217;s IP address to communicate with the <span style="color: #0000ff;">Access point (</span>sign side)</span></p>
<ul>
<li>Change the properties of the <span style="COLOR: #0000ff">Local Area Connection</span>.</li>
<li><span style="COLOR: #000000">Go to <span style="COLOR: #0000ff">Start</span>, <span style="COLOR: #0000ff">Settings</span>, and then <span style="COLOR: #0000ff">Network Connections</span>. </span></li>
<li><span style="COLOR: #000000">Select <span style="COLOR: #0000ff">Local Area Connection </span>and then </span><span style="COLOR: #0000ff">Properties</span><span style="COLOR: #000000">. </span></li>
<li>Scroll down the list and select <span style="COLOR: #0000ff">Internet Protocol (TCP/IP)</span><span style="COLOR: #000000">. </span></li>
<li>Select<strong> </strong><span style="COLOR: #0000ff">Use the following IP address</span><span style="COLOR: #0000ff"> </span>and enter an <strong>IP address</strong> that is similar to the<strong> </strong><span style="color: #0000ff;">Bridge,</span> <span style="COLOR: #ff0000">except </span>for the <strong>last two digits</strong>.</li>
<li>Connect an <span style="COLOR: #ff0000">Ethernet </span><span style="COLOR: #ff0000">crossover cable </span>from the <strong>PC </strong>to the<a title="Moxa NPort 5130" href="http://www.moxa.com/product/NPort_5130.htm"></a><span style="COLOR: #008000"><span style="COLOR: #339966"><a title="Moxa NPort 5130" href="http://www.moxa.com/product/NPort_5130.htm"></a></span><span style="COLOR: #000000"> <span style="color: #0000ff;">Bridge</span></span></span><span style="COLOR: #008000"><span style="COLOR: #000000">.</span></span></li>
</ul>
<p style="text-align: center;"><span style="COLOR: #008000"><span style="COLOR: #000000"><img class="size-full wp-image-3301  aligncenter" title="TCP IP" src="http://www.manuauto.com/wp-content/uploads/2010/03/TCP-IP.jpg" alt="TCP IP" width="404" height="448" /></span></span></p>
<p><span style="color: #0000ff;"><span style="color: #000000;">       </span></span></p>
<p><span style="color: #0000ff;"><span style="color: #000000;">       <span style="text-decoration: underline;"> Site Survey using <span style="color: #008000;">Windows Explorer</span></span></span></span></p>
<ul>
<li>Open Windows Explorer</li>
<li>In the address bar type <a href="ftp://192.168.1.231">ftp://192.168.1.231</a> and click GO. <span style="color: #0000ff;"> </span></li>
</ul>
<p style="text-align: center;"><span style="color: #0000ff;">     </span><span style="color: #0000ff;"><img class="size-full wp-image-3305      aligncenter" title="windows explorer" src="http://www.manuauto.com/wp-content/uploads/2010/03/windows-explorer.jpg" alt="windows explorer" width="271" height="202" /></span></p>
<p> </p>
<ul>
<li>At the login prompt, type <span style="color: #0000ff;">admin </span>for the Username and Password</li>
<li>The <span style="color: #0000ff;">EnGenius </span>main screen will appear.</li>
<li>Click on <span style="color: #0000ff;">Wireless Network </span></li>
</ul>
<p style="text-align: center;"><img class="aligncenter size-full wp-image-3347" title="Wireless Network" src="http://www.manuauto.com/wp-content/uploads/2010/03/Wireless-Network1.jpg" alt="Wireless Network" width="450" height="377" />      </p>
<ul>
<li>The <span style="color: #0000ff;">Wireless Network </span>screen will appear.</li>
<li>Click the <span style="color: #0000ff;">Site Survey </span>button.</li>
</ul>
<p style="text-align: center;">          <img class="aligncenter size-full wp-image-3349" title="Stite survey" src="http://www.manuauto.com/wp-content/uploads/2010/03/Stite-survey2.jpg" alt="Stite survey" width="450" height="377" /></p>
<ul>
<li>The <span style="color: #0000ff;">Site Survey <span style="color: #000000;">sreen w</span></span><span style="color: #000000;">ill a</span>ppear.</li>
<li>Look for the <span style="color: #0000ff;">EnGenius </span>radio. If not present, click the refresh button.</li>
<li>If more than one <span style="color: #0000ff;">EnGenius r</span>adio is present, refer to the MAC address of the radio required.</li>
<li>The <span style="color: #0000ff;">Signal </span>column (dbm) in this window will show the signal strenght.</li>
</ul>
<p style="text-align: center;">                                       <img class="aligncenter" title="Acess Point" src="http://www.manuauto.com/wp-content/uploads/2010/03/Acess-Point1.jpg" alt="Acess Point" width="450" height="377" /></p>
<p style="text-align: center;">         <span style="text-decoration: underline;">Signal Strength Scale Guide</span></p>
<p style="text-align: center;">0 to -50   indicates <span style="color: #ff0000;"><span style="color: #008000;"><strong>Strong</strong> </span></span>signal strength</p>
<p style="text-align: center;">-75 to -100   indicates <span style="color: #ff0000;"><span style="color: #008000;"><strong>Excellent </strong></span></span>signal strength</p>
<p style="text-align: center;">-51 to -75   indicates<strong> </strong><span style="color: #ff0000;"><span style="color: #008000;"><strong>Good</strong> </span></span>signal strength</p>
<p> </p>
<p style="text-align: center;">At<strong> Manufacturers Automation Inc</strong>., we are dedicated to customer service and want to make your experience with Adaptive a pleasant one.</p>
<p style="text-align: center;">© Copyright 2010, Manufacturers Automation Inc.,  <a href="http://www.manuauto.com/"><strong>www.manuauto.com</strong></a></p>
<p style="text-align: center;">
<p style="TEXT-ALIGN: center"> </p>
<address style="TEXT-ALIGN: center">Manufacturers Automation Inc.</address>
<address style="TEXT-ALIGN: center">1600 King Street North</address>
<address style="TEXT-ALIGN: center">P.O. Box 602</address>
<address style="TEXT-ALIGN: center">St. Jacobs, ON N0B 2NO</address>
<address style="TEXT-ALIGN: center">800-387-6268 Tel.      519-664-3300 Tel. </address>
<address style="TEXT-ALIGN: center"><a href="http://www.manuauto.com/"><strong>sales@manuauto.com</strong></a></address>
]]></content:encoded>
			<wfw:commentRss>http://www.manuauto.com/adaptive-wireless-site-survey-model-1650-wifi/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Drive Traffic To Your Business</title>
		<link>http://www.manuauto.com/drive-traffic-to-your-business/</link>
		<comments>http://www.manuauto.com/drive-traffic-to-your-business/#comments</comments>
		<pubDate>Fri, 22 Jan 2010 14:14:45 +0000</pubDate>
		<dc:creator>brent</dc:creator>
				<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.manuauto.com/?p=3242</guid>
		<description><![CDATA[
Adaptive is the leading supplier of led digital signage solutions. Introducing the Excite series, the next generation of full colour outdoor advertising solutions.
The Excite series has been designed to maximize return of advertising, while minimizing energy and maintenance costs. With bright displays and ultra wide viewing angles the Excite series is ideal for any on [...]]]></description>
			<content:encoded><![CDATA[<p><object classid="clsid:d27cdb6e-ae6d-11cf-96b8-444553540000" width="560" height="340" codebase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=6,0,40,0"><param name="allowFullScreen" value="true" /><param name="allowscriptaccess" value="always" /><param name="src" value="http://www.youtube.com/v/qKPcjPw_8RQ&amp;hl=en_GB&amp;fs=1&amp;" /><param name="allowfullscreen" value="true" /><embed type="application/x-shockwave-flash" width="560" height="340" src="http://www.youtube.com/v/qKPcjPw_8RQ&amp;hl=en_GB&amp;fs=1&amp;" allowscriptaccess="always" allowfullscreen="true"></embed></object></p>
<p>Adaptive is the leading supplier of led digital signage solutions. Introducing the Excite series, the next generation of full colour outdoor advertising solutions.</p>
<p>The Excite series has been designed to maximize return of advertising, while minimizing energy and maintenance costs. With bright displays and ultra wide viewing angles the Excite series is ideal for any on or off premise advertising application. With its light weight modular design, the Excite series provides edge to edge viewing without the wasted space seen on bulky framed in configurations and because it&#8217;s equipped with digital pure colour processing, the Excite series renders over 16 million vibrant colours that shine bright in all lighting conditions.</p>
<p>The Excite series is the first all digital led display to use an industry standard DVI architecture for maximise flexibility. This provides straight forward integration with in door signage networks for an enterprise solution and because every Excite ships with Ooh!Media,  Adaptives&#8217; powerful content, creation, and scheduling software. You will have the flexible to instantly deliver targeted exciting digital media that can be produced at a moments notice or scheduled months in advance.</p>
<p>With true Ethernet connectivity and embedded PC control, the Excite series delivers blazing fast file transfers and is capable of displaying real time video content, at up up to 60 frames per second.</p>
<p>Enclosed in Adaptives innovative protector case, environmental containments like dirt and salt spray are virtually eliminated from Excites internal compartments, minimizing maintenance costs and maximizing the life of your investment.</p>
<p>The Excite series is engineered and manufactured by Adaptive, a company with over 30 year of successfully delivering industry leading led display solutions and after sales support with a nation wide network of factory trained partners.</p>
<p><strong><span style="color: #000000;">Courtesy of Adaptive</span></strong></p>
<p style="text-align: center;"><img class="size-full wp-image-3255  aligncenter" title="Adaptive_tagline" src="http://www.manuauto.com/wp-content/uploads/2010/01/Adaptive_tagline1.jpg" alt="Adaptive_tagline" width="175" height="45" /></p>
<p style="text-align: center;"><img class="size-full wp-image-3256  aligncenter" title="Adaptive Excite Outdoor LED Display " src="http://www.manuauto.com/wp-content/uploads/2010/01/Excite2c.jpg" alt="Excite2c" width="102" height="40" /></p>
<p style="text-align: center;">
<p style="text-align: center;">
<p style="text-align: center;">
<p style="text-align: center;">
<p style="text-align: center;">
<p style="text-align: center;">
<p style="text-align: center;">
<p style="text-align: center;">
<p style="text-align: center;">
<p style="text-align: center;">© Copyright 2010, Manufacturers Automation Inc., <a href="../"><strong><span style="color: #666666;">www.manuauto.com</span></strong></a></p>
<address style="text-align: center;">Manufacturers Automation Inc.</address>
<address style="text-align: center;">1600 King Street North</address>
<address style="text-align: center;">P.O. Box 602</address>
<address style="text-align: center;">St. Jacobs, ON N0B 2NO</address>
<address style="text-align: center;">800-387-6268 Tel.      519-664-3300 Tel. </address>
<address style="text-align: center;">519-664-1600 Fax.<br />
</address>
<p style="text-align: center;"><a href="mailto:sales@manuauto.com"><strong><span style="color: #666666;">sales@manuauto.com</span></strong></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.manuauto.com/drive-traffic-to-your-business/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Panasonic Promotion for January 2010 &#8211; Fully Expandable PLC</title>
		<link>http://www.manuauto.com/panasonic-promotion-for-january-2010-plc/</link>
		<comments>http://www.manuauto.com/panasonic-promotion-for-january-2010-plc/#comments</comments>
		<pubDate>Thu, 14 Jan 2010 17:31:20 +0000</pubDate>
		<dc:creator>bbracken</dc:creator>
				<category><![CDATA[Products]]></category>

		<guid isPermaLink="false">http://www.manuauto.com/?p=3234</guid>
		<description><![CDATA[
During the Month of January 2010 only Panasonic Ideas for Life have a Fully Expandable PLC package for only $299.00 CAD. Touch Screen with pass through feature.
The package includes:

1 - PLC &#8211; AFPX-C14R
1 - 5ft Cable &#8211; AFC1500-US
1 - Touch Screen &#8211; AIGT0030B1
3 Year Warranty Included
Plus PLC &#38; HMI software package
All for $299.00 (Regular value $407.00)

The regular price [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: center;"><img class="size-full wp-image-3235 alignnone" title="Special_PLC" src="http://www.manuauto.com/wp-content/uploads/2010/01/Special_PLC.jpg" alt="Special_PLC" width="556" height="500" /></p>
<p>During the Month of January 2010 only Panasonic Ideas for Life have a Fully Expandable PLC package for only $299.00 CAD. Touch Screen with pass through feature.</p>
<p>The package includes:</p>
<ul>
<li>1 - PLC &#8211; AFPX-C14R</li>
<li>1 - 5ft Cable &#8211; AFC1500-US</li>
<li>1 - Touch Screen &#8211; AIGT0030B1</li>
<li>3 Year Warranty Included</li>
<li>Plus PLC &amp; HMI software package</li>
<li>All for $299.00 (Regular value $407.00)</li>
</ul>
<p>The regular price for this package is $407.00 but you can get the Fully Expandable PLC Package for $299.00 Canadian Dollars till the end of January.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.manuauto.com/panasonic-promotion-for-january-2010-plc/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Tamperproof XStream Wireless Modems</title>
		<link>http://www.manuauto.com/tamperproof-xstream-wireless-modems/</link>
		<comments>http://www.manuauto.com/tamperproof-xstream-wireless-modems/#comments</comments>
		<pubDate>Wed, 06 Jan 2010 19:01:06 +0000</pubDate>
		<dc:creator>brent</dc:creator>
				<category><![CDATA[News]]></category>
		<category><![CDATA[MaxStream XStream manul]]></category>
		<category><![CDATA[MaxStream XStream X09-009PKC-R]]></category>
		<category><![CDATA[security code MaxStream wirless modem]]></category>
		<category><![CDATA[tamperproof MaxStream wireless modem]]></category>
		<category><![CDATA[Vendor Identification (VID) Number]]></category>

		<guid isPermaLink="false">http://www.manuauto.com/?p=3153</guid>
		<description><![CDATA[by Brent Raynor – www.manuauto.com
Overview
MaxStream XStream wireless modems can now be security coded by applying a Vendor Identification (VID) number. This procedure will protect against unwanted intruders.
Procedure

Connect the MaxStream XStream to the computer using a straight through serial cable.
Only dip switch 1 is in the on position.
Apply power to the XStream.
Open the MaxStream X-CTU software. [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: center;">by Brent Raynor – <a href="../"><strong>www.manuauto.com</strong></a></p>
<p><strong><span style="text-decoration: underline;">Overview</span></strong></p>
<p>MaxStream XStream wireless modems can <span style="color: #ff6600;"><strong><em>now</em> </strong></span>be security coded by applying a Vendor Identification (VID) number. This procedure will protect against unwanted intruders.</p>
<p><strong><span style="text-decoration: underline;">Procedure</span></strong></p>
<ul>
<li>Connect the MaxStream XStream to the computer using a straight through serial cable.</li>
<li>Only<strong> d</strong><strong>ip switch</strong><strong> <span style="color: #008000;">1</span></strong><span style="color: #008000;"> </span>is in the <strong><span style="color: #008000;">on</span></strong> position.</li>
<li>Apply power to the XStream.</li>
<li>Open the MaxStream X-CTU software. Should a Windows error box appear it means the XStream unit is <strong><span style="color: #ff0000;">not</span></strong> connected to the computer.</li>
<li>Select the<strong><span style="color: #0000ff;"> Modem Configuration</span></strong> tab and the <span style="color: #0000ff;"><strong>Read</strong></span> tab to acquire the modem parameters. A Version box will appear. In order for this procedure to work<strong><span style="color: #ff6600;"> change </span></strong>the version to<span style="color: #0000ff;"> <span style="color: #ff6600;"><strong>42B5</strong></span></span> .</li>
</ul>
<p style="text-align: center;"><img class="aligncenter size-medium wp-image-3201" title="X-CTU Modem Configuration Tab" src="http://www.manuauto.com/wp-content/uploads/2010/01/XSTREAM12-235x300.jpg" alt="X-CTU Modem Configuration Tab" width="240" height="300" /></p>
<ul>
<li>Select the <strong><span style="color: #0000ff;">Write</span></strong> tab and at the bottom of the screen will appear <strong>Complete</strong>.</li>
</ul>
<p style="text-align: center;"><img class="aligncenter size-medium wp-image-3206" title="X-CTU Modem Configuration" src="http://www.manuauto.com/wp-content/uploads/2010/01/XSTREAM23-235x300.jpg" alt="X-CTU Modem Configuration" width="240" height="300" /></p>
<ul>
<li>Select the <strong><span style="color: #0000ff;">Terminal </span></strong>tab to enter <strong>AT commands</strong>.</li>
<li>Holding down the the shift key and typing<strong> <span style="color: #0000ff;">+++</span></strong> <strong> </strong>simutaenously will acknowledge an <strong><span style="color: #ff0000;">OK</span></strong>.  If necessary repeat this step until you see the <strong><span style="color: #ff0000;">OK</span></strong><span style="color: #ff0000;"><span style="color: #000000;">.</span></span></li>
<li>Continue the following steps in a timely manner or you will have to repeat the above step. <span style="color: #0000ff;"><br />
</span></li>
</ul>
<p style="text-align: center;"><img class="aligncenter size-medium wp-image-3159" title="X-CTU Terminal Mode" src="http://www.manuauto.com/wp-content/uploads/2010/01/xstream14-240x300.jpg" alt="X-CTU Terminal Mode" width="240" height="300" /></p>
<ul>
<li>Type<strong> <span style="color: #0000ff;">atid </span></strong>and the <strong>VID code</strong> of the modem will appear in <strong><span style="color: #ff0000;">red</span></strong>.</li>
</ul>
<p style="text-align: center;"><img class="aligncenter size-medium wp-image-3163" title="X-CTU Terminal Mode" src="http://www.manuauto.com/wp-content/uploads/2010/01/XStream2-233x300.jpg" alt="X-CTU Terminal Mode" width="240" height="300" /></p>
<ul>
<li>Type <strong><span style="color: #0000ff;">atid 4444</span></strong> as the new number and press the <strong><span style="color: #0000ff;">Enter Key</span></strong>. The <strong><span style="color: #ff0000;">Ok</span></strong> will appear.</li>
</ul>
<p style="text-align: center;"><img class="aligncenter size-medium wp-image-3172" title="X-CTU Terminal Mode" src="http://www.manuauto.com/wp-content/uploads/2010/01/Xstream-4-236x300.jpg" alt="X-CTU Terminal Mode" width="240" height="300" /></p>
<ul>
<li>This new number must be saved to non-volatile memory using a <strong><span style="color: #0000ff;">Write Command</span></strong> (ATWR) .  Otherwise, the VID code revert to the orginal number when the modem is powered off and then on again.</li>
<li>Type <strong><span style="color: #0000ff;">atwr </span></strong><span style="color: #0000ff;"><span style="color: #000000;">and press the</span></span><strong><span style="color: #0000ff;"> Enter Key. </span></strong><span style="color: #000000;"><strong><span style="color: #ff0000;">OK </span></strong>will appear.</span><strong><span style="color: #0000ff;"> </span></strong></li>
</ul>
<p style="text-align: center;"><img class="aligncenter size-medium wp-image-3178" title="X-CTU Terminal Mode" src="http://www.manuauto.com/wp-content/uploads/2010/01/Xstream-43-236x300.jpg" alt="X-CTU Terminal Mode" width="240" height="300" /></p>
<ul>
<li>Type <strong><span style="color: #0000ff;">atcn </span></strong>to exit the command mode.</li>
<li>Repeat this step for the corresponding XStream wireless modem.</li>
</ul>
<p><img class="aligncenter size-medium wp-image-3181" title="X-CTU Terminal Mode" src="http://www.manuauto.com/wp-content/uploads/2010/01/XSTREAM-5-234x300.jpg" alt="X-CTU Terminal Mode" width="240" height="300" /></p>
<p><a href="http://ftp1.digi.com/support/documentation/productmanual_xstream_pkgr_rs232rs485rfmodem_v5.x00.pdf">http://ftp1.digi.com/support/documentation/productmanual_xstream_pkgr_rs232rs485rfmodem_v5.x00.pdf</a> (MaxStream X09-009PKC-R manual)</p>
<p><a href="http://www.manuauto.com/decimal-to-hexadecimal-converter/">http://www.manuauto.com/decimal-to-hexadecimal-converter/</a> (Hex Converter)</p>
<p><span style="font-size: large; font-family: Times New Roman;"><span style="font-size: medium;"><span style="font-size: small;"><span style="font-size: x-small;"><span style="font-size: xx-small;"><strong> </strong></span></span></span></span></span></p>
<p style="text-align: center;">© Copyright 2010, Manufacturers Automation Inc., <a href="../"><strong><span style="color: #666666;">www.manuauto.com</span></strong></a></p>
<p style="text-align: center;">
<address style="text-align: center;">Manufacturers Automation Inc.</address>
<address style="text-align: center;">1600 King Street North</address>
<address style="text-align: center;">P.O. Box 602</address>
<address style="text-align: center;">St. Jacobs, ON N0B 2NO</address>
<address style="text-align: center;">800-387-6268 Tel.      519-664-3300 Tel. </address>
<address style="text-align: center;">519-664-1600 Fax.<br />
</address>
<address style="text-align: center;"><a href="mailto:sales@manuauto.com"><strong><span style="color: #666666;">sales@manuauto.com</span></strong></a><br />
</address>
]]></content:encoded>
			<wfw:commentRss>http://www.manuauto.com/tamperproof-xstream-wireless-modems/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Maxstream 9XTend Modems Will Not Transmit</title>
		<link>http://www.manuauto.com/maxstream-9xtend-wireless-modems-will-not-transmit-data/</link>
		<comments>http://www.manuauto.com/maxstream-9xtend-wireless-modems-will-not-transmit-data/#comments</comments>
		<pubDate>Tue, 22 Dec 2009 22:32:59 +0000</pubDate>
		<dc:creator>brent</dc:creator>
				<category><![CDATA[News]]></category>
		<category><![CDATA[Maxstream (Digi) RF Modems]]></category>
		<category><![CDATA[Maxstream (Digi) wireless modems]]></category>
		<category><![CDATA[MaxStream 9XTend RF Modems]]></category>
		<category><![CDATA[Maxstream 9XTend Troubleshooting]]></category>
		<category><![CDATA[Maxstream Power Adapters]]></category>

		<guid isPermaLink="false">http://www.manuauto.com/?p=2826</guid>
		<description><![CDATA[ by Brent Raynor – www.manuauto.com
 
Overview



Red power led is on.
X-CTU software (Maxstream) does not detect the 9XTend modem.
Can ping the MaxStream (Digi) ethernet wireless modem.
Yellow and green I/O leds are not flickering simultaneously during transmit.


 Solution


Remove the original power adapter (JP4P2-9V4-6F). The technical specifications are 120VAC,  60Hz with an output is 9VDC at  400mA.  The defective unit may have an [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: center;"> by Brent Raynor – <a href="../"><strong>www.manuauto.com</strong></a></p>
<h2 style="text-align: center;"><strong><span style="color: #0000ff;"> </span></strong></h2>
<p style="text-align: left;"><span style="color: #0000ff;"><span style="text-decoration: underline;"><span style="color: #000000;"><strong>Overview</strong><br />
</span></span></span></p>
<p style="text-align: center;">
<ul>
<li><span style="color: #008000;"><span style="color: #000000;"><span style="color: #ff0000;"><strong>Red</strong></span> power led</span><strong> </strong></span>is <span style="color: #008000;"><span style="color: #000000;"><strong>on</strong></span></span>.</li>
<li><strong>X-CTU software</strong> (Maxstream) does <span style="color: #ff0000;"><strong>not </strong></span>detect the 9XTend modem.</li>
<li>Can ping the MaxStream (Digi) ethernet wireless modem.</li>
<li><strong><span style="color: #ff9900;">Yellow</span></strong> and <strong><span style="color: #008000;">green</span></strong> I/O leds are <strong><span style="color: #ff0000;">not </span></strong>flickering simultaneously during transmit.</li>
</ul>
<p style="text-align: center;"><img class="aligncenter" title="Maxstream 9XTend RF Modem LEDs" src="http://www.manuauto.com/wp-content/uploads/2009/12/Maxstream-Picture-Web1-300x300.jpg" alt="Maxstream indication leds" width="250" height="250" /></p>
<div><strong><span style="font-size: xx-small;"><strong><span style="font-size: xx-small;"> </span></strong></span></strong><strong><span style="color: #0000ff;"><span style="text-decoration: underline;"><span style="color: #000000;">Solution</span></span></span></strong></div>
<p style="text-align: center;">
<ul>
<li>Remove the original power adapter (JP4P2-9V4-6F). The technical specifications are 120VAC,  60Hz with an output is <strong><span style="color: #0000ff;">9VDC </span></strong><span style="color: #0000ff;"><span style="color: #000000;">at </span></span><span style="color: #000000;"> </span>400mA.  The <strong><span style="color: #ff0000;">defective unit</span></strong> may have an output of  <strong><span style="color: #ff0000;">12.75VDC<span style="color: #000000;">. </span></span></strong><span style="color: #ff0000;"><span style="color: #000000;">The Maxstream 9XTend wireless modem will power accordingly; however, the circuitry inside is in an overload state.</span></span><span style="color: #ff0000;"><span style="color: #000000;"> </span></span><span style="color: #ff0000;"> </span><strong><span style="color: #ff0000;"><br />
</span></strong></li>
<li>The<em> </em><span style="color: #008000;"><strong><span style="color: #000000;"><em>new </em></span></strong><span style="color: #000000;">power adapter</span></span><strong> </strong>( JRSP2-9V11-6F Rev A) is 100 -120VAC, 47-63Hz with an output of <strong><span style="color: #0000ff;">9VDC<span style="color: #000000;"><strong> </strong></span></span></strong>at 0.5Amp, will <span style="color: #008000;"><strong>fix</strong></span> this problem.</li>
</ul>
<p style="text-align: center;"><img class="size-medium wp-image-3068  aligncenter" title="Old Maxstream power adapter   P/N: JP4P2-9V4-6F     " src="http://www.manuauto.com/wp-content/uploads/2009/12/DSCF0072-Revised-Web1-300x224.jpg" alt="DSCF0072 Revised Web" width="181" height="132" /><img class="size-medium wp-image-3069 alignnone" title="New Maxstream Power Adapter    P/N: JRSP2-9V11-6F Rev A" src="http://www.manuauto.com/wp-content/uploads/2009/12/DSCF0071-Revised-Web-300x224.jpg" alt="DSCF0071 Revised Web" width="181" height="132" /></p>
<p style="text-align: center;"> </p>
<p style="text-align: center;"><span style="color: #0000ff;"><span style="color: #000000;"><a href="http://www.digi.com/pdf/ds_xtend.pdf"><span style="color: #3366ff;">http://www.digi.com/pdf/ds_xtend.pdf</span></a>  (MaxStream 9XTend datasheet)</span></span></p>
<p style="text-align: center;">
<p style="text-align: center;"><span style="color: #000080;"> </span><a href="http://ftp1.digi.com/support/documentation/productmanual_xtend_pkgr_rs232rs485rfmodem.pdf"><span style="color: #3366ff;">http://ftp1.digi.com/support/documentation/productmanual_xtend_pkgr_rs232rs485rfmodem.pdf</span></a><span style="color: #000080;"><span style="color: #3366ff;">  <span style="color: #000000;">(</span></span></span>MaxStream 9XTend manual)</p>
<p style="text-align: center;"> </p>
<p style="text-align: center;">
<p style="text-align: center;">At<strong> Manufacturers Automation Inc</strong>., we are dedicated to customer service and want to make your experience with Maxstream (Digi) a pleasant one.</p>
<p align="center">© Copyright 2009, Manufacturers Automation Inc., <a href="../"><strong>www.manuauto.com</strong></a></p>
<p style="text-align: center;">
<address style="text-align: center;">Manufacturers Automation Inc.</address>
<address style="text-align: center;">1600 King Street North</address>
<address style="text-align: center;">P.O. Box 602</address>
<address style="text-align: center;">St. Jacobs, ON N0B 2NO</address>
<address style="text-align: center;">800-387-6268 Tel.      519-664-3300 Tel. </address>
<address style="text-align: center;"><a href="mailto:sales@manuauto.com"><strong>sales@manuauto.com</strong></a> </address></p>
]]></content:encoded>
			<wfw:commentRss>http://www.manuauto.com/maxstream-9xtend-wireless-modems-will-not-transmit-data/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Moxa Turbo Chain Technology &#8211; Multiple Redundant Connections</title>
		<link>http://www.manuauto.com/moxa-turbo-chain-technology-multiple-redundant-connections/</link>
		<comments>http://www.manuauto.com/moxa-turbo-chain-technology-multiple-redundant-connections/#comments</comments>
		<pubDate>Fri, 16 Oct 2009 21:13:03 +0000</pubDate>
		<dc:creator>bbracken</dc:creator>
				<category><![CDATA[Articles]]></category>
		<category><![CDATA[Boundless Expansion]]></category>
		<category><![CDATA[Chains]]></category>
		<category><![CDATA[Deployment]]></category>
		<category><![CDATA[Ethernet Network]]></category>
		<category><![CDATA[Ethernet Switches]]></category>
		<category><![CDATA[Existing Network]]></category>
		<category><![CDATA[Maximum Flexibility]]></category>
		<category><![CDATA[Milliseconds]]></category>
		<category><![CDATA[Moxa]]></category>
		<category><![CDATA[Network Failures]]></category>
		<category><![CDATA[Oil Pipeline]]></category>
		<category><![CDATA[Recovery Time]]></category>
		<category><![CDATA[Redundancy]]></category>
		<category><![CDATA[Redundant Connections]]></category>
		<category><![CDATA[Redundant Network]]></category>
		<category><![CDATA[Restriction]]></category>
		<category><![CDATA[Ring Connections]]></category>
		<category><![CDATA[Technology Breakthrough]]></category>
		<category><![CDATA[Topography]]></category>
		<category><![CDATA[Wind Power]]></category>

		<guid isPermaLink="false">http://www.manuauto.com/?p=2795</guid>
		<description><![CDATA[Moxa Turbo Chain technology breakthrough for forming Multiple Redundant Connections.
Best redundant solutions beyond redundant ring technologies by realizing Flexible Topology, Fast Fault Recover and Cost effective configuration. Providing you with the maximum flexibility and expandability possible.

Turbo chain is versatile enough to be used with any topography simply link the two ends of your switch chain [...]]]></description>
			<content:encoded><![CDATA[<p>Moxa Turbo Chain technology breakthrough for forming Multiple Redundant Connections.</p>
<p>Best redundant solutions beyond redundant ring technologies by realizing Flexible Topology, Fast Fault Recover and Cost effective configuration. Providing you with the maximum flexibility and expandability possible.</p>
<p style="text-align: center;"><object classid="clsid:d27cdb6e-ae6d-11cf-96b8-444553540000" width="425" height="344" codebase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=6,0,40,0"><param name="allowFullScreen" value="true" /><param name="allowscriptaccess" value="always" /><param name="src" value="http://www.youtube.com/v/5vWyx8lw4tY&amp;hl=en&amp;fs=1&amp;" /><param name="allowfullscreen" value="true" /><embed type="application/x-shockwave-flash" width="425" height="344" src="http://www.youtube.com/v/5vWyx8lw4tY&amp;hl=en&amp;fs=1&amp;" allowfullscreen="true" allowscriptaccess="always"></embed></object></p>
<p>Turbo chain is versatile enough to be used with any topography simply link the two ends of your switch chain to your Ethernet network and your done.</p>
<p>Boundless Expansion.  Turbo chain makes network extension easy and engineers no longer need to reconfigure the existing network. Moxa Turbo Chain also inter-operates with other redundant protocols.</p>
<p>Now you can create any type of redundant network flexibly and with any restriction.</p>
<p>Fast Fault Recover in under 20 milliseconds.</p>
<p>With Turbo Chains ultra redundancy you can instantly recover from network failures. If a network link fails turbo chain activates the blocked path and and continues forwarding data all in a recovery time less that 20 milliseconds.</p>
<p>Cost saving deployment ring couplings use to interconnect different rings for distributed applications.</p>
<p>Compared with coupling turbo chains flexible topography requires fewer coupling cables and fewer Ethernet ports. Moxa&#8217;s Turbo Chain has been successfully used in numerous applications such as Oil Pipeline, Wind Power, Railway especially those that require multi ring connections.</p>
<p>All Moxa managed Ethernet switches are managed with redundant turbo chain technology.</p>
<p>So why wait start and deploy your networks with Turbo Chain today.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.manuauto.com/moxa-turbo-chain-technology-multiple-redundant-connections/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Moxa NPort S8000 Serial to Ethernet Device &#8211; Overview</title>
		<link>http://www.manuauto.com/moxa-nport-s8000-serial-to-ethernet-device-overview/</link>
		<comments>http://www.manuauto.com/moxa-nport-s8000-serial-to-ethernet-device-overview/#comments</comments>
		<pubDate>Mon, 12 Oct 2009 15:09:04 +0000</pubDate>
		<dc:creator>bbracken</dc:creator>
				<category><![CDATA[Products]]></category>
		<category><![CDATA[Compact Size]]></category>
		<category><![CDATA[Complete Hardware]]></category>
		<category><![CDATA[device servers]]></category>
		<category><![CDATA[Ethernet Connections]]></category>
		<category><![CDATA[Fault Recovery]]></category>
		<category><![CDATA[Fiber Ports]]></category>
		<category><![CDATA[Hardware Protection]]></category>
		<category><![CDATA[Network Connections]]></category>
		<category><![CDATA[Power Source]]></category>
		<category><![CDATA[Practical Applications]]></category>
		<category><![CDATA[Ring Configuration]]></category>
		<category><![CDATA[Rs 232]]></category>
		<category><![CDATA[Rs 422]]></category>
		<category><![CDATA[Rs 485]]></category>
		<category><![CDATA[Safety Ring]]></category>
		<category><![CDATA[Self Healing]]></category>
		<category><![CDATA[Serial Device Server]]></category>
		<category><![CDATA[Serial Ports]]></category>
		<category><![CDATA[Surge Protection]]></category>
		<category><![CDATA[Vlan]]></category>

		<guid isPermaLink="false">http://www.manuauto.com/?p=2793</guid>
		<description><![CDATA[Moxa NPort S8000 Serial to Ethernet Device &#8211; Overview
Combo switch and device server. NPort S8000 Series Industrial Ethernet Switch. Moxa switches support turbo raid Fastest self healing technology that provides fault recovery of less than 20 ms and allows for a larger ring configuration. Moxa Device Servers are rugged and reliable. Easy to use Serial [...]]]></description>
			<content:encoded><![CDATA[<p><strong>Moxa NPort S8000 Serial to Ethernet Device &#8211; Overview</strong></p>
<p>Combo switch and device server. NPort S8000 Series Industrial Ethernet Switch. Moxa switches support turbo raid Fastest self healing technology that provides fault recovery of less than 20 ms and allows for a larger ring configuration. Moxa Device Servers are rugged and reliable. Easy to use Serial to Ethernet connectivity.  All in one design for greater versatility.</p>
<p><strong>Each NPort S8000 includes:</strong></p>
<ul>
<li>2 fiber ports</li>
<li>3 Ethernet Ports</li>
<li>4 RS-232/422/485 Serial Ports</li>
</ul>
<p><strong>The Moxa NPort S8000 Supports Several Serial to Ethernet Functions:</strong></p>
<ul>
<li>Serial Device Server RS-232, RS-422, RS-485, Real COMM and RFC 2217.</li>
<li>Industrial Ethernet Switch Turbo Ring, RSTP, VLAN, Qos and 802.1x.</li>
</ul>
<p>Complete Hardware Protection that Includes Surge Protection for the Power Source, Serial and Ethernet Connections.</p>
<ul>
<li>2 KV Serial Isolation</li>
<li>Full Surge Protection</li>
<li>Level 4 ESD</li>
<li>UL508 Safety</li>
</ul>
<p>Ring Redundancy at the Device Level &#8211; Ethernet Redundancy at the Device Level.</p>
<p>Watch the video for some practical applications.</p>
<p>Compact size makes the NPort S8000 is the best solution for your projects.</p>
<p>The NPort S8000 simplifies your Industrial Network Connections.</p>
<p style="text-align: center;"><object classid="clsid:d27cdb6e-ae6d-11cf-96b8-444553540000" width="425" height="344" codebase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=6,0,40,0"><param name="allowFullScreen" value="true" /><param name="allowscriptaccess" value="always" /><param name="src" value="http://www.youtube.com/v/4zCf9WhGsVw&amp;hl=en&amp;fs=1&amp;" /><param name="allowfullscreen" value="true" /><embed type="application/x-shockwave-flash" width="425" height="344" src="http://www.youtube.com/v/4zCf9WhGsVw&amp;hl=en&amp;fs=1&amp;" allowfullscreen="true" allowscriptaccess="always"></embed></object></p>
]]></content:encoded>
			<wfw:commentRss>http://www.manuauto.com/moxa-nport-s8000-serial-to-ethernet-device-overview/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Moxa&#8217;s Serial to Fiber Converter Family Introduction</title>
		<link>http://www.manuauto.com/moxas-serial-to-fiber-converter-family-introduction/</link>
		<comments>http://www.manuauto.com/moxas-serial-to-fiber-converter-family-introduction/#comments</comments>
		<pubDate>Fri, 09 Oct 2009 02:59:39 +0000</pubDate>
		<dc:creator>bbracken</dc:creator>
				<category><![CDATA[Products]]></category>

		<guid isPermaLink="false">http://www.manuauto.com/?p=2786</guid>
		<description><![CDATA[
Moxa&#8217;s Serial to Fiber Converter Family Introduction
Moxa&#8217;s serial to fiber converters which include TCF-90 and TCF-142 for entry level, ICF-1150 series for industrial grade and NRack System for high density solution. Also include CP-102UF which is a multiport serial board with fiber optic interface.
The TCF-142 media converter is equipped with a multiple interface circuit that [...]]]></description>
			<content:encoded><![CDATA[<p><img class="alignright size-full wp-image-2787" title="Moxa RS-232/422/485 to optical fiber media converters" src="http://www.manuauto.com/wp-content/uploads/2009/10/2149200841717191.jpg" alt="Moxa RS-232/422/485 to optical fiber media converters" width="300" height="150" /></p>
<p><strong>Moxa&#8217;s Serial to Fiber Converter Family Introduction</strong></p>
<p>Moxa&#8217;s serial to fiber converters which include TCF-90 and TCF-142 for entry level, ICF-1150 series for industrial grade and NRack System for high density solution. Also include CP-102UF which is a multiport serial board with fiber optic interface.</p>
<p>The TCF-142 media converter is equipped with a multiple interface circuit that can handle RS-232 or RS-422/485 serial interfaces and multi-mode or single-mode fiber. TCF-142 converters are used to extend serial transmission up to 5 km (TCF-142-M with multi-mode fiber) or up to 40 km (TCF-142-S with single-mode fiber). The TCF-142 can be configured to convert either RS-232 signals, or RS-422/485 signals, but not both at the same time.</p>
<p style="text-align: center;"><object classid="clsid:d27cdb6e-ae6d-11cf-96b8-444553540000" width="425" height="344" codebase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=6,0,40,0"><param name="allowFullScreen" value="true" /><param name="allowscriptaccess" value="always" /><param name="src" value="http://www.youtube.com/v/V8c7ew5p7MI&amp;hl=en&amp;fs=1&amp;" /><param name="allowfullscreen" value="true" /><embed type="application/x-shockwave-flash" width="425" height="344" src="http://www.youtube.com/v/V8c7ew5p7MI&amp;hl=en&amp;fs=1&amp;" allowfullscreen="true" allowscriptaccess="always"></embed></object></p>
]]></content:encoded>
			<wfw:commentRss>http://www.manuauto.com/moxas-serial-to-fiber-converter-family-introduction/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
