Ethernet to Serial Device

Adaptive Serial Clocks on a TCP/IP Network

by Brent Raynor www.manuauto.com

serial clock 11 Adaptive Serial Clocks on a TCP/IP Network

1033-1113 Adaptive Serial Clock

serial clock12 1024x689 Adaptive Serial Clocks on a TCP/IP Network

Connect an Adaptive serial clock to the LAN

Product Required

  • 1033-1113 Adaptive Serial Clock
  • NPort 5130 Moxa Serial Device Server
  • 71220204 Indoor RS485 Communication Wire and DB9(f) Connector
  • 43310602LF Modular Network Adapter
  • 1088-8636 1 Ft. RS-485 Cable with 2 RJ11s & Ferrite

Windows XP Setup for Configuring the Moxa NPort 5130

  • Change the properties of the Local Area Connection.
  • Go to Start, Settings, and then Network Connections.
  • Select Local Area Connection and then Properties.
  • Scroll down the list and select Internet Protocol (TCP/IP).
  • Select Use the following IP address and enter an IP address that is similar to the Moxa NPort 5130, except for the last two digits.
  • Connect an Ethernet crossover cable from the PC to the Moxa NPort 5130.
  • Apply power to the Moxa NPort 5130.

Moxa Configuration Software

  • Install the NPort Administration Suite
  • http://www.moxa.com/support/download.aspx?d_id=1317
  • Select the Configuration tab, under the Function heading.
  • Select the Search tab and the configuration information will appear. The factory default IP address is 192.168.127.254
  • Select COM Mapping tab, under the Function heading.
  • Select the Add tab and the information for the Moxa NPort 5130 will appear.
  • Select From List, click on the box next to the information and select OK.
  • The Com Port can be changed by double clicking on the information tab. Choose Com 4 for this example.
  • Click the Apply tab and a window will appear Do you want to apply the changes. Select Yes.

Adaptive EtherTime Software

At Manufacturers Automation Inc., we are dedicated to customer service and want to make your experience with Adaptive led displays and Moxa serial device servers, a pleasant one.

© Copyright 2009, Manufacturers Automation Inc., www.manuauto.com

Manufacturers Automation Inc.
1600 King Street North
P.O. Box 602
St. Jacobs, ON N0B 2NO
800-387-6268 Tel. 519-664-3300 Tel.
sales@manuauto.com

Moxa Ethernet Connectivity for the Adaptive StreetSmart

by Brent Raynor

Hardware Required

  • Moxa NPort 5110 (1-port RS-232 serial device server)
  • Sticky Velcro Strip (3″)
  • Adaptive P/N: 1179122301 (power cable)
  • Serial cable 9Pin(f) to 9Pin(m)

nport 51104 Moxa Ethernet Connectivity for the Adaptive StreetSmart power cable2 300x243 Moxa Ethernet Connectivity for the Adaptive StreetSmart

Configure the Moxa NPort 5110

nport 5110 pic1 300x210 Moxa Ethernet Connectivity for the Adaptive StreetSmart

  • Double click on the NPort 5110 line and configuration box will appear.

nport 5110 pic2 300x211 Moxa Ethernet Connectivity for the Adaptive StreetSmart

  • Select the Network tab and then Modify. a) IP Address b) Netmask c) Gateway

nport 5110 pic3 300x210 Moxa Ethernet Connectivity for the Adaptive StreetSmart

  • Select the Serial tab, check Modify and double click on the settings.
  • Once the serial settings box appears, enter the baud settings and click OK.
  • 9600, 8, N, 1
  • No Flow Control
  • FIFO Enabled
  • RS-232

nport 5110 pic4 300x215 Moxa Ethernet Connectivity for the Adaptive StreetSmart

  • Select the Operating Mode tab, then Modify.
  • Double click the TCP Server Mode line.
  • Operating Mode: Server Mode
  • Local TCP Port: 3001
  • Command Port: 966
  • Max. Connection: 1
  • TCP Alive Check 7
  • Inactivity Timeout 0
  • Click Ok.

nport 5110 pic6 300x209 Moxa Ethernet Connectivity for the Adaptive StreetSmartnport 5110 pic51 300x212 Moxa Ethernet Connectivity for the Adaptive StreetSmart

  • Click OK again and the new configuration is downloaded to the Moxa NPort 5110.

nport 5110 pic7 300x211 Moxa Ethernet Connectivity for the Adaptive StreetSmart

Hardware installation, StreetSmart 17X (only)

  • Locate the boost regulator board inside the display, on the rear side of the driver board led panel.
  • Plug the power cable (P/N: 1179122301) in the output of the boost regulator board. The purpose of this board is to step up the 5VDC to 9VDC. Then plug the socket end of the power cable into the Moxa NPort 5110.
  • Note: StreetSmart 35X or AlphaEclipse displays do not have a boost regulator board. Recommend a din rail AC recepticle to mount the power adapter, which is included with the Moxa NPort5110.

pic1 300x225 Moxa Ethernet Connectivity for the Adaptive StreetSmart

power booster6 300x209 Moxa Ethernet Connectivity for the Adaptive StreetSmart

  • Connect the serial cable from the Moxa NPort 5110 to the Com1 port of the Adaptive controller board. Adhere the velcro strip for mounting purposes.
  • Then connect the Ethernet 10/100 Base T(x) cable into the Moxa NPort 5110.

revised picture 300x225 Moxa Ethernet Connectivity for the Adaptive StreetSmart

Test the Moxa NPort 5110

  • Open the diagnostic program in AlphaNet.
  • Select TCP/IP and then Setup.
  • Enter the IP Address and Port (3001).
  • Click on the Ping IP Address tab and a reply will appear. This procedure verifys connectivity to the Moxa NPort 5110.
  • picture1 300x230 Moxa Ethernet Connectivity for the Adaptive StreetSmart

  • The next step is to transmit a test message.
  • A -> Click the Connect TCPIP tab under Actions.
  • B -> The TCP/IP State will change to connected.
  • C -> Click on the Broadcast Message tab.
  • D -> Click on the Select Address tab and a pop-up screen will appear. Add the StreetSmart address to the list and the Sign Type is AlphaEclipse StreetSmart V. Click Ok.
  • E -> Select Continuous Transmit and then the Send tab. View the messages on the StreetSmart led display.
  • picture2b 300x228 Moxa Ethernet Connectivity for the Adaptive StreetSmart

    picture4 300x229 Moxa Ethernet Connectivity for the Adaptive StreetSmart