<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Manufacturers Automation              1-800-387-6268 &#187; Ethernet to Serial Device</title>
	<atom:link href="http://www.manuauto.com/tag/ethernet-to-serial-device/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.manuauto.com</link>
	<description>Automation and Device Networking - M.A.P.P.</description>
	<lastBuildDate>Mon, 02 Jan 2012 14:53:29 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3</generator>
		<item>
		<title>Adaptive Serial Clocks on a TCP/IP Network</title>
		<link>http://www.manuauto.com/adaptive-serial-clocks-on-a-tcpip-network/</link>
		<comments>http://www.manuauto.com/adaptive-serial-clocks-on-a-tcpip-network/#comments</comments>
		<pubDate>Mon, 04 May 2009 15:46:49 +0000</pubDate>
		<dc:creator>brent</dc:creator>
				<category><![CDATA[News]]></category>
		<category><![CDATA[Adaptive EtherTime Software]]></category>
		<category><![CDATA[Adaptive Micro Systems]]></category>
		<category><![CDATA[Adaptive Serial Clock Software]]></category>
		<category><![CDATA[Administration Suite]]></category>
		<category><![CDATA[Alpha Serial Clock]]></category>
		<category><![CDATA[Ethernet Crossover Cable]]></category>
		<category><![CDATA[Ethernet to Serial Device]]></category>
		<category><![CDATA[Moxa serial device server]]></category>
		<category><![CDATA[Network Adapter]]></category>
		<category><![CDATA[Network Connections]]></category>
		<category><![CDATA[NPort 5130]]></category>
		<category><![CDATA[NPort Administration Suite]]></category>
		<category><![CDATA[Serial Clock Connected to Ethernet]]></category>
		<category><![CDATA[Serial Device Server]]></category>
		<category><![CDATA[serial to ethernet]]></category>

		<guid isPermaLink="false">http://www.manuauto.com/?p=1810</guid>
		<description><![CDATA[by Brent Raynor www.manuauto.com Connect an Adaptive serial clock to the LAN Product Required 1033-1113 Adaptive Serial Clock NPort 5130 Moxa Serial Device Server 71220204 Indoor RS485 Communication Wire and DB9(f) Connector 43310602LF Modular Network Adapter 1088-8636 1 Ft. RS-485 Cable with 2 RJ11s &#38; Ferrite Windows XP Setup for Configuring the Moxa NPort 5130 [...]]]></description>
			<content:encoded><![CDATA[<!-- Start Shareaholic LikeButtonSetTop Automatic --><!-- End Shareaholic LikeButtonSetTop Automatic --><p style="text-align: center;">by Brent Raynor  <a href="../"><strong>www.manuauto.com</strong></a></p>
<p style="text-align: center;">
<div id="attachment_1885" class="wp-caption aligncenter" style="width: 320px"><a href="http://www.ams-i.com/Indoor%20LED%20Signs/1LineDisplays/Media/Alpha%20Serial%20Clock_97033003C.pdf"><img class="size-full wp-image-1885    " title="Adaptive Serial Clock" src="http://www.manuauto.com/wp-content/uploads/2009/05/serial-clock-11.jpg" alt="serial clock 11 Adaptive Serial Clocks on a TCP/IP Network" width="310" height="160" /></a><p class="wp-caption-text">1033-1113 Adaptive Serial Clock</p></div>
<p style="text-align: center;"><a href="http://www.moxa.com/product/nport_5150.htm"></a></p>
<h2 style="text-align: center;"><a href="http://www.moxa.com/product/nport_5150.htm"><img class="aligncenter size-large wp-image-2052" title="Adaptive Serial Clock and Moxa Serial Device Server" src="http://www.manuauto.com/wp-content/uploads/2009/05/serial-clock12-1024x689.jpg" alt="serial clock12 1024x689 Adaptive Serial Clocks on a TCP/IP Network" width="614" height="413" /></a> <span style="color: #0000ff;"> </span></h2>
<h2 style="text-align: center;"><strong> </strong><span style="color: #0000ff;">Connect an Adaptive serial clock to the LAN</span></h2>
<p style="text-align: left;"><span style="text-decoration: underline;">Product Required</span></p>
<ul>
<li>
<div style="text-align: left;">1033-1113                Adaptive Serial Clock</div>
</li>
<li>
<div style="text-align: left;">NPort 5130               Moxa Serial Device Server</div>
</li>
<li>
<div style="text-align: left;">71220204                 Indoor RS485 Communication Wire and DB9(f) Connector</div>
</li>
<li>
<div style="text-align: left;">43310602LF              Modular Network Adapter</div>
</li>
<li>
<div style="text-align: left;">1088-8636                1 Ft. RS-485 Cable with 2 RJ11s &amp; Ferrite</div>
</li>
</ul>
<p style="text-align: left;"><a title="Moxa NPort 5130" href="http://www.moxa.com/product/NPort_5130.htm"><span style="text-decoration: underline;">Windows XP Setup for Configuring the <span style="color: #008000;">Moxa NPort 5130</span></span></a></p>
<ul>
<li>Change the properties of the <span style="color: #0000ff;">Local Area Connection</span>.</li>
<li><span style="color: #000000;">Go to <span style="color: #0000ff;">Start</span>, <span style="color: #0000ff;">Settings</span>, and then <span style="color: #0000ff;">Network Connections</span>. </span></li>
<li><span style="color: #000000;">Select <span style="color: #0000ff;">Local Area Connection </span>and then </span><span style="color: #0000ff;">Properties</span><span style="color: #000000;">. </span></li>
<li>Scroll down the list and select <span style="color: #0000ff;">Internet Protocol (TCP/IP)</span><span style="color: #000000;">. </span></li>
<li>Select<strong> </strong><span style="color: #0000ff;">Use the following IP address</span><span style="color: #0000ff;"> </span>and enter an <strong>IP address</strong> that is similar to the<strong> </strong><a title="Moxa NPort 5130" href="http://www.moxa.com/product/NPort_5130.htm"><span style="color: #008000;">Moxa NPort 5130</span></a>, <span style="color: #ff0000;">except </span>for the <strong>last two digits</strong>.</li>
<li>Connect an <span style="color: #ff0000;">Ethernet </span><span style="color: #ff0000;">crossover cable </span>from the <strong>PC </strong>to the<a title="Moxa NPort 5130" href="http://www.moxa.com/product/NPort_5130.htm"></a><span style="color: #008000;"><span style="color: #339966;"><a title="Moxa NPort 5130" href="http://www.moxa.com/product/NPort_5130.htm"></a></span><span style="color: #000000;"> </span></span><a title="Moxa NPort 5130" href="http://www.moxa.com/product/NPort_5130.htm"><span style="color: #008000;">Moxa NPort 5130</span></a><span style="color: #008000;"><span style="color: #000000;">.</span></span></li>
<li>Apply power to the <a title="Moxa NPort 5130" href="http://www.moxa.com/product/NPort_5130.htm"><span style="color: #008000;">Moxa NPort 5130</span></a>.</li>
</ul>
<p style="text-align: left;"><span style="text-decoration: underline;"><span style="color: #008000;">Moxa</span> Configuration </span><span style="color: #008000;"><span style="text-decoration: underline;"><span style="color: #000000;">Software</span></span></span></p>
<ul>
<li>Install the <span style="color: #008000;">NPort Administration Suite </span></li>
<li><span style="color: #008000;"><span style="color: #008000;"><a href="http://www.moxa.com/support/download.aspx?d_id=1317"><strong><span style="color: #666666;">http://www.moxa.com/support/download.aspx?d_id=1317</span></strong></a></span> </span></li>
<li>Select the <span style="color: #008000;">Configuration</span> tab, under the <span style="color: #0000ff;">Function <span style="color: #000000;">heading.</span></span></li>
<li>Select the <span style="color: #008000;">Search</span> tab and the configuration information will appear.  The factory default IP address is  192.168.127.254</li>
<li>Select <span style="color: #008000;">COM Mapping <span style="color: #000000;">tab, </span></span>under the <span style="color: #0000ff;">Function <span style="color: #000000;">heading</span></span>.</li>
<li>Select the <span style="color: #008000;">Add</span> tab and the information for the <a title="Moxa NPort 5130" href="http://www.moxa.com/product/NPort_5130.htm"><span style="color: #008000;">Moxa NPort 5130</span></a> will appear.</li>
<li><span style="color: #0000ff;"><span style="color: #008000;">Select From List</span>, </span><span style="color: #000000;">click on the <strong>box</strong> next to the information and select <strong>OK</strong>.</span></li>
<li>The <strong>Com Port</strong> can be changed by double clicking on the information tab.  Choose <strong>Com 4</strong> for this example.</li>
<li>Click the <span style="color: #008000;">Apply</span> tab and a window will appear <span style="color: #0000ff;">Do you want to apply the changes</span>. Select <strong>Yes.</strong></li>
</ul>
<p><span style="color: #0000ff;"><span style="text-decoration: underline;">Adaptive EtherTime Software</span> </span></p>
<ul>
<li>
<div style="text-align: left;">Install the weblink below.</div>
</li>
<li>
<div style="text-align: left;"><a href="http://www.manuauto.com/support/adaptive/adaptive-software-downloads/">http://www.manuauto.com/support/adaptive/adaptive-software-downloads/</a></div>
</li>
<li>
<div style="text-align: left;"><span style="color: #0000ff;"><strong>Ethertime</strong></span> syncs the serial clocks to the time on the PC or Server.</div>
</li>
</ul>
<p style="text-align: left;">
<p style="text-align: left;"><span style="font-size: large; font-family: Times New Roman;"><span style="font-size: medium;"><span style="font-size: small;"><span style="font-size: x-small;"><span style="font-size: xx-small;"><span style="font-size: large; font-family: Times New Roman;"><span style="font-size: medium;"><span style="font-size: small;">At<strong> Manufacturers Automation Inc</strong>., we are dedicated to customer service and want to make your experience with Adaptive led displays and Moxa serial device servers, a pleasant one. </span></span></span></span></span></span></span></span></p>
<p style="text-align: center;">
<p style="text-align: center;">©  Copyright 2009, Manufacturers Automation Inc., <a href="http://www.manuauto.com"><strong><span style="color: #666666;">www.manuauto.com</span></strong></a></p>
<p style="text-align: center;">
<address style="text-align: center;">Manufacturers Automation Inc.</address>
<address style="text-align: center;">1600 King Street North</address>
<address style="text-align: center;">P.O. Box 602</address>
<address style="text-align: center;">St. Jacobs, ON N0B 2NO</address>
<address style="text-align: center;">800-387-6268 Tel.      519-664-3300 Tel. </address>
<address style="text-align: center;"><a href="mailto:sales@manuauto.com"><strong><span style="color: #666666;">sales@manuauto.com</span></strong></a> </address>
<input id="gwProxy" type="hidden" />
<input id="jsProxy" onclick="jsCall();" type="hidden" />
<input id="gwProxy" type="hidden" />
<input id="jsProxy" onclick="jsCall();" type="hidden" />
<input id="gwProxy" type="hidden" />
<input id="jsProxy" onclick="jsCall();" type="hidden" />
<input id="gwProxy" type="hidden" />
<input id="jsProxy" onclick="jsCall();" type="hidden" />
<input id="gwProxy" type="hidden" />
<input id="jsProxy" onclick="jsCall();" type="hidden" />
<input id="gwProxy" type="hidden" />
<input id="jsProxy" onclick="jsCall();" type="hidden" />
<input id="gwProxy" type="hidden" />
<input id="jsProxy" onclick="jsCall();" type="hidden" />
<input id="gwProxy" type="hidden" />
<input id="jsProxy" onclick="jsCall();" type="hidden" />
<input id="gwProxy" type="hidden" />
<input id="jsProxy" onclick="jsCall();" type="hidden" />
<input id="gwProxy" type="hidden" />
<input id="jsProxy" onclick="jsCall();" type="hidden" />
<div class="shr-publisher-1810"></div><!-- Start Shareaholic LikeButtonSetBottom Automatic --><!-- End Shareaholic LikeButtonSetBottom Automatic -->]]></content:encoded>
			<wfw:commentRss>http://www.manuauto.com/adaptive-serial-clocks-on-a-tcpip-network/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Moxa Ethernet Connectivity for the Adaptive StreetSmart</title>
		<link>http://www.manuauto.com/moxa-ethernet-connectivity-for-adaptive-streetsmart/</link>
		<comments>http://www.manuauto.com/moxa-ethernet-connectivity-for-adaptive-streetsmart/#comments</comments>
		<pubDate>Wed, 07 Jan 2009 14:23:39 +0000</pubDate>
		<dc:creator>brent</dc:creator>
				<category><![CDATA[News]]></category>
		<category><![CDATA[Adaptive Controller Picture]]></category>
		<category><![CDATA[Controller Board]]></category>
		<category><![CDATA[Cross Over Cable]]></category>
		<category><![CDATA[Ethernet Connectivity]]></category>
		<category><![CDATA[Ethernet Connectivity for Adaptive StreetSmart]]></category>
		<category><![CDATA[Ethernet to Serial Device]]></category>
		<category><![CDATA[Moxa Administration Suite]]></category>
		<category><![CDATA[Moxa NPort 5110]]></category>
		<category><![CDATA[Serial Device Server]]></category>
		<category><![CDATA[Server Mode]]></category>
		<category><![CDATA[Streetsmart]]></category>
		<category><![CDATA[Tcp Server]]></category>

		<guid isPermaLink="false">http://www.manuauto.com/?p=1026</guid>
		<description><![CDATA[by Brent Raynor Hardware Required Moxa NPort 5110 (1-port RS-232 serial device server) Sticky Velcro Strip (3&#8243;) Adaptive P/N: 1179122301 (power cable) Serial cable 9Pin(f) to 9Pin(m) Configure the Moxa NPort 5110 Connect a cross-over cable from the PC to the Moxa NPort 5110. Open the Moxa NPort Administration Suite software http://www.moxa.com/support/download.aspx?d_id=1317 Select Configuration, then [...]]]></description>
			<content:encoded><![CDATA[<!-- Start Shareaholic LikeButtonSetTop Automatic --><!-- End Shareaholic LikeButtonSetTop Automatic --><p>by Brent Raynor <a href="http://www.manuauto.com"></p>
<p style="text-align: left;"><span style="text-decoration: underline;">Hardware Required</span></p>
<ul>
<li>
<div style="text-align: left;"><span style="color: #008000;">Moxa NPort 5110 </span>(1-port RS-232 serial device server)</div>
</li>
<li>
<div style="text-align: left;">Sticky Velcro Strip (3&#8243;)</div>
</li>
<li>
<div style="text-align: left;"><strong>Adaptive</strong> P/N: 1179122301 (power cable)</div>
</li>
<li>
<div style="text-align: left;">Serial cable 9Pin(f) to 9Pin(m)</div>
</li>
</ul>
<p style="text-align: center;"><span style="font-size: x-small; font-family: Times New Roman;">     <a href="http://www.manuauto.com/wp-content/uploads/2009/01/nport-51104.jpg"><img class="alignnone size-medium wp-image-1100" title="NPort 5110 Serial Device Server" src="http://www.manuauto.com/wp-content/uploads/2009/01/nport-51104.jpg" alt="nport 51104 Moxa Ethernet Connectivity for the Adaptive StreetSmart" width="300" height="150" /></a><a title="Moxa NPort 5110" href="http://www.moxa.com/product/NPort_5110.htm"></a></span><span style="font-size: x-small; font-family: Times New Roman;">      </span><span style="font-size: x-small; font-family: Times New Roman;"><a href="http://www.manuauto.com/wp-content/uploads/2009/01/power-cable2.jpg"><img class="size-medium wp-image-1047  aligncenter" title="1179122301   Power Cable" src="http://www.manuauto.com/wp-content/uploads/2009/01/power-cable2-300x243.jpg" alt="power cable2 300x243 Moxa Ethernet Connectivity for the Adaptive StreetSmart" width="165" height="81" /></a></span></p>
<p style="text-align: left;"><span style="font-size: x-small; font-family: Times New Roman;">  </span><span style="font-size: x-small; font-family: Times New Roman;">       </span><span style="text-decoration: underline;">Configure the <span style="color: #008000;">Moxa NPort 5110</span></span></p>
<ul>
<li>Connect a <span style="color: #ff0000;">cross-over cable </span>from the PC to the <span style="color: #008000;">Moxa NPort 5110</span>.</li>
<li>Open the <span style="color: #008000;">Moxa </span><span style="color: #000000;">NPort Administration Suite software </span><a href="http://www.moxa.com/support/download.aspx?d_id=1317">http://www.moxa.com/support/download.aspx?d_id=1317</a></li>
<li>Select <span style="color: #0000ff;">Configuration</span>, then <span style="color: #0000ff;">Broadcast Search</span></li>
</ul>
<p style="text-align: center;"><a href="http://www.manuauto.com/wp-content/uploads/2009/01/nport-5110-pic1.jpg"><img class="size-medium wp-image-1050 aligncenter" title="nport-5110-pic1" src="http://www.manuauto.com/wp-content/uploads/2009/01/nport-5110-pic1-300x210.jpg" alt="nport 5110 pic1 300x210 Moxa Ethernet Connectivity for the Adaptive StreetSmart" width="300" height="210" /></a></p>
<ul>
<li>
<div style="text-align: left;">Double click on the <span style="color: #008000;">NPort 5110 </span>line and configuration box will appear. </div>
</li>
</ul>
<p style="text-align: center;"><img class="size-medium wp-image-1053   aligncenter" title="nport-5110-pic2" src="http://www.manuauto.com/wp-content/uploads/2009/01/nport-5110-pic2-300x211.jpg" alt="nport 5110 pic2 300x211 Moxa Ethernet Connectivity for the Adaptive StreetSmart" width="300" height="211" /></p>
<ul>
<li>Select the <span style="color: #0000ff;">Network <span style="color: #000000;">tab</span> </span>and then<span style="color: #0000ff;"> Modify</span>.  a) IP Address  b) Netmask  c) Gateway</li>
</ul>
<p style="text-align: center;"><a href="http://www.manuauto.com/wp-content/uploads/2009/01/nport-5110-pic3.jpg"><img class="size-medium wp-image-1055 aligncenter" title="nport-5110-pic3" src="http://www.manuauto.com/wp-content/uploads/2009/01/nport-5110-pic3-300x210.jpg" alt="nport 5110 pic3 300x210 Moxa Ethernet Connectivity for the Adaptive StreetSmart" width="300" height="210" /></a></p>
<ul>
<li>Select the <span style="color: #0000ff;">Serial</span> tab, check <span style="color: #0000ff;">Modify</span> and double click on the settings.</li>
<li>Once the serial settings box appears, enter the baud settings and click <span style="color: #0000ff;">OK</span>.</li>
<li>9600, 8, N, 1</li>
<li>No Flow Control</li>
<li>FIFO Enabled</li>
<li>RS-232</li>
</ul>
<p style="text-align: center;"><a href="http://www.manuauto.com/wp-content/uploads/2009/01/nport-5110-pic4.jpg"><img class="size-medium wp-image-1056 aligncenter" title="nport-5110-pic4" src="http://www.manuauto.com/wp-content/uploads/2009/01/nport-5110-pic4-300x215.jpg" alt="nport 5110 pic4 300x215 Moxa Ethernet Connectivity for the Adaptive StreetSmart" width="300" height="215" /></a></p>
<ul>
<li>Select the <span style="color: #0000ff;">Operating Mode </span>tab, then <span style="color: #0000ff;">Modify</span>.</li>
<li>Double click the <span style="color: #0000ff;">TCP Server Mode </span>line.</li>
<li>Operating Mode: Server Mode</li>
<li>Local TCP Port: 3001</li>
<li>Command Port: 966</li>
<li>Max. Connection: 1</li>
<li>TCP Alive Check 7</li>
<li>Inactivity Timeout 0</li>
<li>Click <span style="color: #0000ff;">Ok</span>.</li>
</ul>
<p style="text-align: center;"><a href="http://www.manuauto.com/wp-content/uploads/2009/01/nport-5110-pic6.jpg"><img class="alignnone size-medium wp-image-1060" title="nport-5110-pic6" src="http://www.manuauto.com/wp-content/uploads/2009/01/nport-5110-pic6-300x209.jpg" alt="nport 5110 pic6 300x209 Moxa Ethernet Connectivity for the Adaptive StreetSmart" width="300" height="209" /></a><a href="http://www.manuauto.com/wp-content/uploads/2009/01/nport-5110-pic51.jpg"><img class="size-medium wp-image-1059   aligncenter" title="nport-5110-pic51" src="http://www.manuauto.com/wp-content/uploads/2009/01/nport-5110-pic51-300x212.jpg" alt="nport 5110 pic51 300x212 Moxa Ethernet Connectivity for the Adaptive StreetSmart" width="300" height="212" /></a></p>
<ul>
<li>Click <span style="color: #0000ff;">OK </span>again and the new configuration is downloaded to the <span style="color: #008000;">Moxa</span> <span style="color: #008000;">NPort 5110</span>.</li>
</ul>
<p style="text-align: center;"><img class="size-medium wp-image-1062 aligncenter" title="nport-5110-pic7" src="http://www.manuauto.com/wp-content/uploads/2009/01/nport-5110-pic7-300x211.jpg" alt="nport 5110 pic7 300x211 Moxa Ethernet Connectivity for the Adaptive StreetSmart" width="300" height="211" /></p>
<p>        <span style="text-decoration: underline;">Hardware installation, StreetSmart 17X (only)</span></p>
<ul>
<li>Locate the <span style="color: #0000ff;">boost regulator board <span style="color: #000000;">inside the display, on the rear side of the driver board led panel.</span></span></li>
<li>Plug the power cable (P/N: 1179122301) in the output of the <span style="color: #0000ff;">boost regulator board</span><span style="font-size: x-small; font-family: Times New Roman;"><span style="color: #0000ff;">.  </span></span>The purpose of this board is to step up the 5VDC to 9VDC.  Then plug the socket end of the power cable into the <span style="color: #008000;">Moxa NPort 5110</span><span style="color: #000000;">. </span></li>
<li><strong>Note:</strong>  StreetSmart 35X or AlphaEclipse<strong> </strong>displays do <span style="color: #ff0000;">not</span> have a <span style="color: #0000ff;">boost regulator board</span>.  Recommend a din rail AC recepticle to mount the power adapter, which is included with the <span style="color: #008000;">Moxa NPort5110</span>.</li>
</ul>
<p style="text-align: center;"><a href="http://www.manuauto.com/wp-content/uploads/2009/01/pic1.jpg"><img class="size-medium wp-image-1063   aligncenter" title="pic1" src="http://www.manuauto.com/wp-content/uploads/2009/01/pic1-300x225.jpg" alt="pic1 300x225 Moxa Ethernet Connectivity for the Adaptive StreetSmart" width="300" height="225" /></a></p>
<p style="text-align: center;"> <a href="http://www.manuauto.com/wp-content/uploads/2009/01/power-booster3.jpg"></a><a href="http://www.manuauto.com/wp-content/uploads/2009/01/power-booster2.jpg"></a><a href="http://www.manuauto.com/wp-content/uploads/2009/01/power-booster1.jpg"></a><a href="http://www.manuauto.com/wp-content/uploads/2009/01/power-booster.jpg"></a></p>
<p><a href="http://www.manuauto.com/wp-content/uploads/2009/01/power-booster4.jpg"></a></p>
<p style="text-align: center;"><a href="http://www.manuauto.com/wp-content/uploads/2009/01/power-booster6.jpg"><img class="alignnone size-medium wp-image-1073" title="power-booster6" src="http://www.manuauto.com/wp-content/uploads/2009/01/power-booster6-300x209.jpg" alt="power booster6 300x209 Moxa Ethernet Connectivity for the Adaptive StreetSmart" width="300" height="209" /></a></p>
<ul>
<li>
<div style="text-align: left;">Connect the serial cable from the <span style="color: #008000;">M</span><span style="color: #008000;">oxa NPort 5110 <span style="color: #000000;">to</span> </span>the <strong>Com1</strong> port of the <strong>Adaptive </strong>controller board.  Adhere the velcro strip for mounting purposes.</div>
</li>
<li>
<div style="text-align: left;">Then connect the <strong>Ethernet</strong> 10/100 Base T(x) cable into the <span style="color: #008000;">Moxa NPort 5110</span>.</div>
</li>
</ul>
<p style="text-align: center;"><a href="http://www.manuauto.com/wp-content/uploads/2009/01/pic2.jpg"></a></p>
<p style="text-align: center;"><a href="http://www.manuauto.com/wp-content/uploads/2009/01/revised-picture.jpg"><img class="size-medium wp-image-1108 aligncenter" title="revised-picture" src="http://www.manuauto.com/wp-content/uploads/2009/01/revised-picture-300x225.jpg" alt="revised picture 300x225 Moxa Ethernet Connectivity for the Adaptive StreetSmart" width="300" height="225" /></a></p>
<p>       <span style="text-decoration: underline;">Test the <span style="color: #008000;">Moxa NPort 5110</span></span></p>
<ul>
<li><span style="color: #000000;">Open the <span style="color: #0000ff;">diagnostic program </span>in </span><span style="color: #0000ff;">AlphaNet.</span></li>
<li><span style="color: #0000ff;"><span style="color: #000000;">Select</span> TCP/IP <span style="color: #000000;">and then </span>Setup<span style="color: #000000;">.</span></span></li>
<li>Enter the IP Address and Port (3001).</li>
<li>Click on the <span style="color: #0000ff;">Ping IP Address</span> tab and a reply will appear. This procedure verifys connectivity to the <span style="color: #008000;">Moxa NPort 5110</span>.</li>
<p style="text-align: center;"><img class="size-medium wp-image-1079 aligncenter" title="picture1" src="http://www.manuauto.com/wp-content/uploads/2009/01/picture1-300x230.jpg" alt="picture1 300x230 Moxa Ethernet Connectivity for the Adaptive StreetSmart" width="300" height="230" /></p>
<li>The next step is to transmit a test message.</li>
<li>A -&gt; Click the <span style="color: #0000ff;">Connect TCPIP </span>tab under Actions.</li>
<li>B -&gt; The <span style="color: #0000ff;">TCP/IP State </span>will change to <strong>connected</strong>.</li>
<li>C -&gt; Click on the <span style="color: #0000ff;">Broadcast Message </span>tab.</li>
<li>D -&gt; Click on the <span style="color: #0000ff;">Select</span> <span style="color: #0000ff;">Address <span style="color: #000000;">tab and a pop-up </span><span style="color: #000000;">screen will appear.  Add the StreetSmart address to the list and the <span style="color: #0000ff;">Sign Type </span>is <span style="color: #0000ff;">AlphaEclipse StreetSmart V</span>.  Click Ok.</span></span></li>
<li>E  -&gt; Select <span style="color: #0000ff;">Continuous Transmit <span style="color: #000000;">and then the </span><span style="color: #0000ff;">Send </span><span style="color: #000000;">tab.</span></span><span style="color: #0000ff;"><span style="color: #000000;">  View the messages on the StreetSmart led display. </span>              <a href="http://www.manuauto.com/wp-content/uploads/2009/01/picture2b.jpg"></a></span></li>
<p style="text-align: center;"><img class="size-medium wp-image-1083        aligncenter" title="picture2b" src="http://www.manuauto.com/wp-content/uploads/2009/01/picture2b-300x228.jpg" alt="picture2b 300x228 Moxa Ethernet Connectivity for the Adaptive StreetSmart" width="300" height="228" /></p>
<p style="text-align: center;"><a href="http://www.manuauto.com/wp-content/uploads/2009/01/picture4.jpg"><img class="size-medium wp-image-1085 aligncenter" title="picture4" src="http://www.manuauto.com/wp-content/uploads/2009/01/picture4-300x229.jpg" alt="picture4 300x229 Moxa Ethernet Connectivity for the Adaptive StreetSmart" width="300" height="229" /></a></p>
</ul>
<p style="text-align: center;"><span style="font-size: large; font-family: Times New Roman;"><span style="font-size: medium;"><span style="font-size: small;">At<strong> Manufacturers Automation Inc</strong>., we are dedicated to customer service and want to make your experience with Adaptive led displays, a pleasant one. </span></span></span></p>
<p style="text-align: center;">©  Copyright 2008, Manufacturers Automation Inc., <a href="http://www.manuauto.com/"><strong><span style="color: #666666;">www.manuauto.com</span></strong></a></p>
<p style="text-align: center;">
<address style="text-align: center;">    Manufacturers Automation Inc.</address>
<address style="text-align: center;">1600 King Street North</address>
<address style="text-align: center;">P.O. Box 602</address>
<address style="text-align: center;">St. Jacobs, ON N0B 2NO</address>
<address style="text-align: center;">     800-387-6268  Tel.          519-664-3300 Tel. </address>
<address style="text-align: center;">   <a href="mailto:sales@manuauto.com"><strong><span style="color: #666666;">sales@manuauto.com</span></strong></a></address>
<div class="shr-publisher-1026"></div><!-- Start Shareaholic LikeButtonSetBottom Automatic --><!-- End Shareaholic LikeButtonSetBottom Automatic -->]]></content:encoded>
			<wfw:commentRss>http://www.manuauto.com/moxa-ethernet-connectivity-for-adaptive-streetsmart/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

<!-- Performance optimized by W3 Total Cache. Learn more: http://www.w3-edge.com/wordpress-plugins/

Served from: www.manuauto.com @ 2012-02-09 08:42:33 -->
