	<title>Manufacturers Automation              1-800-387-6268 &#187; Hexadecimal Number</title>
	<atom:link href="http://www.manuauto.com/tag/hexadecimal-number/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.manuauto.com</link>
	<description>Automation and Device Networking - M.A.P.P.</description>
	<lastBuildDate>Mon, 02 Jan 2012 14:53:29 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3</generator>
		<item>
		<title>MaxStream X-CTU Software Setup for the Ethernet 9XTend Wireless Modem</title>
		<link>http://www.manuauto.com/maxstream-x-ctu-setup-for-the-ethernet-9xtend-wireless-modem/</link>
		<comments>http://www.manuauto.com/maxstream-x-ctu-setup-for-the-ethernet-9xtend-wireless-modem/#comments</comments>
		<pubDate>Thu, 12 Feb 2009 21:36:36 +0000</pubDate>
		<dc:creator>brent</dc:creator>
				<category><![CDATA[News]]></category>
		<category><![CDATA[Decimal To Hexadecimal Converter]]></category>
		<category><![CDATA[Ethernet Wireless]]></category>
		<category><![CDATA[Hexadecimal Code]]></category>
		<category><![CDATA[Hexadecimal Number]]></category>
		<category><![CDATA[MaxStream redirector software]]></category>
		<category><![CDATA[MaxStream Security Feature]]></category>
		<category><![CDATA[Network Connections]]></category>
		<category><![CDATA[Serial Converter]]></category>
		<category><![CDATA[Vendor Id]]></category>
		<category><![CDATA[Virtual Com Port]]></category>
		<category><![CDATA[Wireless Modems]]></category>
		<category><![CDATA[X-CTU Software Setup]]></category>

		<guid isPermaLink="false">http://www.manuauto.com/?p=1372</guid>
		<description><![CDATA[by Brent Raynor www.manuauto.com Assigning an IP address to the MaxStream 9XTend ethernet wireless modem involves configuring a computer to act as a network. This is accomplished by modifying the local area connection of the computer. If the computer (laptop) does not have a serial communication port, make sure to install a usb to serial [...]]]></description>
			<content:encoded><![CDATA[<!-- Start Shareaholic LikeButtonSetTop Automatic --><!-- End Shareaholic LikeButtonSetTop Automatic --><div style="text-align: center;"><span style="font-size: 14pt; color: #000000; font-family: 'Times New Roman'; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-language: #00FF; mso-bidi-language: AR-SA; mso-bidi-font-size: 10.0pt;">by Brent Raynor </span><span style="font-size: 10pt; font-family: 'Times New Roman'; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-language: #00FF; mso-bidi-language: AR-SA;"><a href="http://www.manuauto.com/"><span style="color: #666666;"><strong>www.manuauto.com</strong></span></a></span></div>
<div style="text-align: center;"><a href="http://www.manuauto.com/wp-content/uploads/2009/01/pic201.jpg"></a><a href="http://www.manuauto.com/wp-content/uploads/2009/01/pic205.jpg"></a><span style="font-size: 14pt; color: #000000; font-family: 'Times New Roman'; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-language: #00FF; mso-bidi-language: AR-SA; mso-bidi-font-size: 10.0pt;"><a href="http://www.manuauto.com/wp-content/uploads/2009/01/nport-5110.jpg"></a><a href="http://www.manuauto.com/wp-content/uploads/2009/01/nport-51102.jpg"></a><a href="http://www.manuauto.com/wp-content/uploads/2009/01/nport-5110-pic7.jpg"></a><a href="http://www.manuauto.com/wp-content/uploads/2009/01/picture1.jpg"></a><a href="http://www.manuauto.com/wp-content/uploads/2009/01/pic500.jpg"></a></span></div>
<ul>
<li><span style="color: #000000;"><span style="color: #008000;"><span style="color: #000000;"><span style="color: #000000;"><span style="color: #008000;"><span style="color: #000000;">Assigning an IP address to the MaxStream 9XTend <strong>ethernet </strong>wireless modem involves configuring a computer to act as a network.  This is accomplished by modifying the <strong>local area connection </strong>of the computer. </span></span></span></span></span></span></li>
<li><span style="color: #000000;"><span style="color: #008000;"><span style="color: #000000;">If the computer (laptop) does <span style="color: #ff0000;">not </span>have a serial communication port,  make sure to install a usb to serial adapter. The MaxStream X-CTU <span style="color: #0000ff;"><span style="color: #000000;"><strong>redirector software</strong></span> <span style="color: #000000;">must</span> <span style="color: #000000;">be able to </span></span>detect a serial communication port on the computer.</span></span></span></li>
<li><span style="color: #000000;"><span style="color: #008000;"><span style="color: #000000;">Connect a <span style="color: #ff0000;">cross-over </span>ethernet cable from the computer&#8217;s ethernet port to the MaxStream 9XTend&#8217;s ethernet port.</span></span></span></li>
</ul>
<p><span style="color: #000000;"><span style="color: #008000;"><span style="color: #000000;"> </span><span style="color: #000000;"><span style="text-decoration: underline;">Windows XP</span></span></span><span style="color: #000000;"><span style="text-decoration: underline;"><span style="color: #000000;"> </span>Setup</span></span></span></p>
<ul>
<li>Change the properties of the <span style="color: #0000ff;">Local Area Connection</span>.</li>
<li><span style="color: #000000;">Go to <span style="color: #0000ff;">Start</span>, <span style="color: #0000ff;">Settings</span>, and then <span style="color: #0000ff;">Network Connections</span>. </span></li>
<li><span style="color: #000000;">Select <span style="color: #0000ff;">Local Area Connection </span>and then </span><span style="color: #0000ff;">Properties</span><span style="color: #000000;">. </span></li>
<li>Scroll down the list and select <span style="color: #0000ff;">Internet Protocol (TCP/IP)</span><span style="color: #000000;">. </span></li>
<li>Select<strong> </strong><span style="color: #0000ff;">Use the following IP address</span><span style="color: #0000ff;"> </span>and enter <span style="color: #0000ff;">10.1.110.10 </span> The last digit prevents a network conflict</li>
<li><span style="color: #ff0000;">Note: </span> The MaxStream <strong>ethernet</strong> 9XTend factory default IP address is 10.1.110.11</li>
</ul>
<p style="text-align: center;"><img class="aligncenter size-medium wp-image-2077" title="pic123" src="http://www.manuauto.com/wp-content/uploads/2009/02/pic123-243x300.jpg" alt="pic123 243x300 MaxStream X CTU Software Setup for the Ethernet 9XTend Wireless Modem " width="262" height="300" /></p>
<p style="text-align: center;"><img class="size-medium wp-image-2059      aligncenter" title="ip-address1" src="http://www.manuauto.com/wp-content/uploads/2009/02/ip-address1-262x300.jpg" alt="ip address1 262x300 MaxStream X CTU Software Setup for the Ethernet 9XTend Wireless Modem " width="262" height="300" /> <a href="http://www.manuauto.com/wp-content/uploads/2009/02/ip1.jpg"></a></p>
<p><span style="text-decoration: underline;"><span style="color: #000000;">MaxStream 9XTend <span style="color: #0000ff;"><span style="color: #000000;"><strong>Ethernet</strong></span> </span>Wireless Modem Setup</span></span></p>
<ul>
<li>Install the <span style="color: #0000ff;">X-CTU <span style="color: #000000;">and then the</span> Redirector</span> software.</li>
<li>Reboot the computer if prompted to do so.</li>
<li>Open the <span style="color: #0000ff;">X-CTU </span>software.</li>
<li>Enter the <strong>new</strong> <strong>IP address</strong> and make sure the <strong>virtual com port</strong> is <strong>com 5</strong> or above.</li>
<li style="text-align: left;"><span style="color: #000000;">Under <span style="color: #0000ff;">Ch</span><span style="color: #0000ff;">anges</span>, click the <span style="color: #0000ff;">Apply</span> tab to refresh the settings.</span></li>
<li style="text-align: left;">Exit the <span style="color: #0000ff;">X-CTU </span>program and reboot the computer.</li>
</ul>
<p style="text-align: center;"><a href="http://www.manuauto.com/wp-content/uploads/2009/02/xctu11.jpg"><img class="size-medium wp-image-1383 aligncenter" title="xctu11" src="http://www.manuauto.com/wp-content/uploads/2009/02/xctu11-236x300.jpg" alt="xctu11 236x300 MaxStream X CTU Software Setup for the Ethernet 9XTend Wireless Modem " width="262" height="300" /></a></p>
<p style="text-align: center;"><a href="http://www.manuauto.com/wp-content/uploads/2009/02/xctu1.jpg"></a></p>
<p style="text-align: left;"><strong> </strong></p>
<p style="text-align: left;"><strong> </strong> <span style="text-decoration: underline;">Security Feature</span></p>
<ul>
<li>
<div style="text-align: left;">All MaxStream wireless devices have a <span style="color: #0000ff;">VID</span> (Vendor ID) and require a four digit hexadecimal number.</div>
</li>
<li>
<div style="text-align: left;">Choose a four digit number and use the weblink below to convert it to hexadecimal.</div>
</li>
<li>
<div style="text-align: left;"><a href="http://www.manuauto.com/decimal-to-hexadecimal-converter/"><span style="color: #0000ff;"><span style="color: #3366ff;">http://www.manuauto.com/decimal-to-hexadecimal-converter</span>/</span></a><span style="color: #0000ff;"> </span></div>
</li>
<li>
<div style="text-align: left;">Input the four digit hexadecimal code and click the <span style="color: #0000ff;">Write tab </span>to update the configuration .</div>
</li>
</ul>
<p style="text-align: center;"><a href="http://www.manuauto.com/wp-content/uploads/2009/02/vid.jpg"><img class="size-medium wp-image-1373 aligncenter" title="vid" src="http://www.manuauto.com/wp-content/uploads/2009/02/vid-236x300.jpg" alt="vid 236x300 MaxStream X CTU Software Setup for the Ethernet 9XTend Wireless Modem " width="262" height="300" /></a></p>
<p><span style="text-decoration: underline;">MaxStream 9XTend Ethernet and Serial Modems</span></p>
<ul>
<li>Communication between <strong>two </strong>MaxStream 9XTend <span style="color: #0000ff;">Ethernet </span>wireless modems will <span style="color: #ff0000;">not</span> work as a bridge. Since the Ethernet (TCP/IP) protocol is removed by the Ethernet-to-serial converter inside the unit, the radios can only transmit and receive serial data over the air.  A receiving radio in this case, would only see the serial data and all network information would be lost.  This means the network would <span style="color: #ff0000;">not</span> be able to see the remote radio.</li>
<li>The <span style="color: #0000ff;">receiving radio </span>must be a MaxStream 9XTend <span style="color: #0000ff;">serial</span> wireless modem.</li>
<li>Set the MaxStream 9XTend <span style="color: #0000ff;">serial</span><strong> </strong>wireless modem <span style="color: #008000;"><span style="color: #0000ff;">dip switches</span> </span><span style="color: #008000;"><strong>1 &amp; 5</strong></span> in the <span style="color: #008000;"><strong>on</strong> <span style="color: #000000;">position</span></span><span style="color: #000000;">.</span></li>
</ul>
<p><span style="text-decoration: underline;">Troubleshooting</span></p>
<ul>
<li>Disable the wireless on the PC.</li>
<li>Turn off the firewall.</li>
<li>Reboot the computer.</li>
</ul>
<p style="text-align: center;"><span style="font-size: large; font-family: Times New Roman;"><span style="font-size: medium;"><span style="font-size: small;"><span style="font-size: x-small;"><span style="font-size: xx-small;">At<strong> Manufacturers Automation Inc</strong>., we are dedicated to customer service and want to make your experience with Adaptive led displays and the MaxStream RF Modems a pleasant one. </span></span></span></span></span></p>
<p style="text-align: center;">© Copyright 2009, Manufacturers Automation Inc., <a href="http://www.manuauto.com/"><strong><span style="color: #666666;">www.manuauto.com</span></strong></a></p>
<p style="text-align: center;">
<address style="text-align: center;"> </address>
<address style="text-align: center;">Manufacturers Automation Inc.</address>
<address style="text-align: center;">1600 King Street North</address>
<address style="text-align: center;">P.O. Box 602</address>
<address style="text-align: center;">St. Jacobs, ON N0B 2NO</address>
<address style="text-align: center;">800-387-6268 Tel.      519-664-3300 Tel. </address>
<address style="text-align: center;"><a href="mailto:sales@manuauto.com"><strong><span style="color: #666666;">sales@manuauto.com</span></strong></a> </address>
<address style="text-align: center;"></address>
<address style="text-align: center;"></address>
<address style="text-align: center;"><img class="size-medium wp-image-1417 aligncenter" title="ip1" src="http://www.manuauto.com/wp-content/uploads/2009/02/ip1-267x300.jpg" alt="ip1 267x300 MaxStream X CTU Software Setup for the Ethernet 9XTend Wireless Modem " width="267" height="300" /></address>
<div class="shr-publisher-1372"></div><!-- Start Shareaholic LikeButtonSetBottom Automatic --><!-- End Shareaholic LikeButtonSetBottom Automatic -->]]></content:encoded>
			<wfw:commentRss>http://www.manuauto.com/maxstream-x-ctu-setup-for-the-ethernet-9xtend-wireless-modem/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

<!-- Performance optimized by W3 Total Cache. Learn more: http://www.w3-edge.com/wordpress-plugins/
