PULS PIRD20.241 FEATURES
- Cost-Effective Solution to Build Redundant Systems
- Dual Input with Single Output
- Two Diodes (Common Cathode)
- DC 12-28V ±25% Wide-range Input
- Full Power Between -40°C and +55°C
- Width only 39mm
- Large Screw Terminals
- Easy Wiring: Distribution Terminal for Negative Pole Included
PULS PIRD20.241 INTRODUCTION
The MLY02.100 is a simple redundant The PIRD20.241 is a redundancy module that can be used to build 1+1 and N+1 redundant systems. It is equipped with two input channels, which can be connected to power supplies with up to 10A output current, and one output, which can carry nominal currents up to 20A. The module is suitable for power supplies with constant current overload behavior as well as any kind of “hiccup” overload behavior.
The PIRD20.241 is the perfect solution to use in a redundant system if the power supply itself is equipped with a DC-OK signal. Another application for this redundancy module is to separate sensitive loads from non-sensitive loads. This avoids the distortion of the power quality for the sensitive loads, which can cause controller failures.
As an Authorized Distributor of PULS, Manufacturers Automation Inc. (ManuAuto) offers a wide variety of Industrial Automation and Communication products across North America, including Canada (Ontario, Toronto) and the US. Buy PULS PIRD20.241 Diode Redundancy Module online at a competitive price, with on-time delivery and fast shipping services. Our certified engineers are always available to support you.
You can also find the MLY10.241 and MLY02.100 models in the PULS Diode Redundancy Module Series.
PULS PIRD20.241 CERTIFICATIONS

| PULS Power Supply : Input Data | |
| Input Voltage Range | DC: 9 to 35 VDC |
| Nominal Input Voltage | - |
| Input Frequency Range | |
| Input Current | Ambient < +55°C: 2x 0 to 10A, ambient < +70°C: 2x 0 to 6.25A |
| Power Factor | - |
| Crest Factor | - |
| Inrush Current | - |
| Input Fuse | No |
| PULS Power Supply : Output Data | |
| Output Voltage Range | - |
| Nominal Output Voltage | - |
| Output Current | Ambient < +55°C: 2x 0 to 20A, ambient < +70°C: 2x 0 to 12.5A |
| Output Power | - |
| Power Boost | - |
| Output Capacitance | - |
| PULS Power Supply : Protection Features | |
| Overload Protection | Yes |
| Reverse Input Polarity Protection | No |
| Over-Temperature Protection | No |
| Input Transient Protection | Yes: MOV |
| Output Transient Protection | Yes |
| Short Circuit Protection | Yes |
| Output Overvoltage Protection | No |
| PULS Power Supply : General | |
| MTBF | SN 29500: 20310000 h |
| Connection Method | Screw terminals |
| AC/DC OK | DC: Yes |
| LED Indicators | 1 green LED |
| Remote ON / OFF Function | - |
| IO-Link Interface | - |
| PULS Power Supply : Physical Characteristics | |
| Operating Temperature | -40° to 70°C |
| Storage Temperature | -40° to 85°C |
| Relative Humidity Range | 5 to 95% r.H |
| Altitude Range | 0 to 2000m |
| Derating | Between +55 to +70 °C: 6 W/°C |
| Dimensions | 39 mm x 124 mm x 124 mm |
| Weight | 280 g |
| Mounting Type | DIN rail |
| Housing | Polycarbonate |
| Standards and Certifications | EAC, RoHS, WEEE, REACH, EU, VDMA 24364, Class I Div 2, IECEx, ATEX, UL 60950-1, IEC 60950-1, UL 508, IEC 60068-2-6, IEC 60068-2-27 |