BALLUFF BMF00C4 MAGNETIC FIELD SENSOR FOR T-SLOT/ MULTIPLE SLOT SHAPES
- Model: BMF00C4
BALLUFF BMF00C4 FEATURES
- For T-slot
- Connection: M8x1-Male, 3-pin
- Operating temperature: -25 to 85 °C
- IP rating: IP67
- Mounting part: can be installed in the T-slot from above
- Emission: Group 1, Class B
- Reliable switching behavior thanks to precise switchpoints
- Non-contacting and thus free from wear
- Impervious to contamination
BALLUFF BMF00C4 INTRODUCTION
Balluff BMF magnetic field sensors for T-slots can be mounted directly in the groove and distinguish themselves with their particularly strong hold. They can be mounted flush so that they are suitable for space-critical applications.
In addition, Balluff offers extremely short configurations for flexible usage options. The sensors detect the piston position without contact through the cylinder walls. The system is adaptable for cylinders and grippers with both strong and weak magnets.
As an Authorized Distributor of BALLUFF, Manufacturers Automation Inc. (ManuAuto) offers a wide variety of Industrial Automation and Communication products across North America, including Canada (Ontario, Toronto) and the US. Buy BALLUFF BMF00C4 MAGNETIC FIELD SENSOR FOR T-SLOT/ MULTIPLE SLOT SHAPES online at a competitive price, with on-time delivery and fast shipping services. Our certified engineers are always available to support you.
You can also find the BMF00L7 and BMF00MW models in the BALLUFF Magnetic Field Sensors for T-slot.
BALLUFF BMF00C4 CERTIFICATIONS

| Magnetic Field Sensors : Interface | |
| Output Characteristic | PNP normally open (NO) |
| Magnetic Field Sensors : Electrical Connection | |
| Cable Diameter D | 2.50 mm |
| Connection | M8x1-Male, 3-pin |
| Polarity Reversal Protected | No |
| Short-Circuit Protection | Yes |
| Protection Against Device Mix-Ups | No |
| Magnetic Field Sensors : Electrical Data | |
| Load Capacitance Max. at Ue | 1 µF |
| Operating Voltage Ub | 10 to 30 VDC |
| Rated Operating Current Ie | 200 mA |
| Rated Operating Voltage Ue DC | 24 V |
| Ripple Max. (% of Ue) | 15 % |
| Switching Frequency | 3000 Hz |
| Magnetic Field Sensors : Physical/Environmental Features | |
| Dimension | 23.5 x 5 x 5.5 mm |
| Installation | - |
| Temperature | -25 to 85 °C |
| Housing | PA 12 |
| IP Rating | IP67 |
| MTTF | 355 a |
| Tightening Torque | 0.4 Nm |
| Standards and Approvals | cULus, CE, UKCA, WEEE, IEC 60947-5-2 |