Introduction
Photoelectric sensors check presence, shape, colour, distance, and thickness - optimised for robotics, automation, assembly, and handling. They are real experts with various strengths: detecting and counting parts, monitoring stack heights, through-glass detection, aligning small parts, detecting marks, fill level detection, and much more!
Certifications

Features
- Connection: Connector, M12x1-Male, 4-pin
- Operating temperature: -10 to 50 °C
- IP rating: IP67
- Series: 12M
- Principle of optical operation: Through-beam sensor (receiver)
- Range: 0 to 60 m
- Part recognition and counting
- Stack height monitoring
- Detection through glass
| Sensor : Basic features | |
| Approval/Conformity | CE, UKCA, cULus, WEEE |
| Basic standard | IEC 60947-5-2 |
| Sensor : Display/Operation | |
| Function Indicator | _ |
| Power Indicator | _ |
| Sensor : Electrical Connection | |
| Cable diameter D | _ |
| Cable length L | _ |
| Number of conductors | _ |
| Sensor : Electrical Data | |
| Operating Voltage Ub | 10 to 30 VDC |
| Output Resistance Ra | _ |
| Protection Class | II |
| Switching Frequency | 1500 Hz |
| Sensor : Environmental Conditions | |
| EN 60068-2-27, Shock | Half-sinus, 30 g , 11 ms, 3x6 |
| EN 60068-2-6, Vibration | 10 to 55 Hz, amplitude 1 mm, 3x30 min |
| Sensor : Functional Safety | |
| MTTF (40 °C) | 453 a |
| Sensor : Interface | |
| Switching Output | PNP normally closed (NC), PNP normally open (NO) Pins 4-2 |
| Sensor : Material | |
| Housing Material | Zinc, Die casting, Powder coated, Aluminium |
| Material Jacket | _ |
| Material Sensing Surface | PMMA |
| Sensor : Mechanical Data | |
| Dimension | 15 x 50 x 42.5 mm |
| Installation | _ |
| Size | _ |
| Sensor : Range/Distance | |
| Assured Operating Distance Sa | _ |
| Rated Operating Distance Sn | 60 m Adjustable |
| Real Switching Distance sr | _ |