MOXA EDS-208A-M-SC Unmanaged Ethernet Switch
- Model: EDS-208A-M-SC
MOXA EDS-208A-M-SC INTRODUCTION
The Moxa EDS-208A-M-SC unmanaged Ethernet switch is
excellent for delivering stable, efficient network connectivity in environments
where reliability is non-negotiable. As part of the Moxa EDS-208A Series, this
device plays a critical role within unmanaged switches used across industrial Ethernet infrastructures, enabling consistent data communication without the
complexity of configuration. The Moxa EDS-208A-M-SC integrates seamlessly into
railway transportation, oil and gas facilities, road transportation systems,
water and wastewater operations, marine networks, and factory automation
environments where vibration, temperature variation, and electrical noise are
common challenges. Its hardware design includes seven 10/100BaseT(X) Ethernet
ports with RJ45 connectors and one 100BaseFX multimode fiber port with an SC
connector, which enables flexible copper-to-fiber network extensions while
maintaining signal integrity. With an operating temperature range of –10 to
60°C, the switch is well-suited for continuous industrial operation. These
features are the sole reason why the Moxa EDS-208A-M-SC switch is a dependable
choice for engineers looking to build resilient networks. For a deeper
technical overview, engineers can refer to the Moxa EDS-208A-M-SC datasheet.
As an Authorized Distributor of MOXA, Manufacturers Automation Inc. (ManuAuto) offers a wide variety of Industrial Automation and Communication products across North America, including Canada (Ontario, Toronto) and the US. Buy MOXA EDS-208A-M-SC Unmanaged Ethernet Switch online at a competitive price, with on-time delivery and fast shipping services. Our certified engineers are always available to support you.
You can also find the EDS-208A, EDS-208A-M-ST, EDS-208A-S-SC, and EDS-208A-T models in the MOXA EDS-208A Series.
MOXA EDS-208A-M-SC CERTIFICATIONS
From a compliance and durability standpoint, the
EDS-208A-M-SC switch is engineered to meet the most resilient industrial and
transportation standards for mission-critical deployments. The switch complies
with EMC, EMI, EMS, and safety requirements, ensuring reliable performance in
electrically noisy environments. It is also tested for vibration and shock
resistance, supporting installation in moving or mechanically demanding
systems. Certifications such as EN 50121-4 for railway applications and maritime
approvals, including ABS, DNV-GL, LR, and NK, highlight its suitability for
transportation and marine use cases, while ATEX and Class I Division 2
hazardous location compliance confirm its readiness for oil and gas
installations. Engineers seeking detailed compliance information, installation
guidance, and extended specifications are encouraged to review the Moxa EDS-208A-M-SC manual.

| Switch and Hub : Interface | |
| Number of ports | 8 Ports |
| 10/100Mb RJ45 (Megabit) Ports | Yes : 7 Ports |
| 10/100/1000Mb RJ45 (Gigabit) Ports | No |
| 100Mb Fiber optic multi mode (Megabit) Ports | Yes : 1 Port (SC connector) |
| 100Mb Fiber optic single mode (Megabit) Ports | No |
| 100Mb SFP Fiber optic (Megabit) Ports | No |
| 1000Mb SFP Fiber optic (Gigabit) Ports | No |
| 10/100Mb (Megabit) POE Ports | No |
| 10/100/1000Mb (Gigabit) POE Ports | No |
| Other ports | No |
| Switch and Hub : Features and Capabilities | |
| Backup | No |
| Switch and Hub : LED Indicators | |
| LED Per Port | Yes |
| Switch and Hub : Power Requirements | |
| Input Voltage | 12/24/48 VDC |
| Input Current | 0.11 A @ 24 VDC |
| Operating Voltage | 9.6 to 60 VDC |
| Power Input Plugin ( Redundant ) | Yes |
| Power Consumption | - |
| Switch and Hub : General | |
| Fan / Fanless | Fanless |
| MTBF | 2,943,335 hrs |
| Switch and Hub : Switch Specifications | |
| Most forwarding speed | - |
| Network working layers | Layer 1 |
| Switch type | UnManaged |
| Port Aggregation | No |
| Switch and Hub : Physical Characteristics | |
| Dimensions | 50 x 114 x 70 mm (1.96 x 4.49 x 2.76 in) |
| Housing | Aluminum |
| Installation | DIN-rail mounting, Wall mounting (with optional kit) |
| Operating Temperature | -10 to 60°C (14 to 140°F) |
| Operation Humidity | 5 to 95% (non-condensing) |
| Standards and Certifications | Safety: UL 508, EN 62368-1 (LVD); EMC: EN 55032/35; EMI: CISPR 32, FCC Part 15B Class A; EMS: IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m, IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV, IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV, IEC 61000-4-6 CS: 10 V, IEC 61000-4-8 PFMF; Hazardous Locations: ATEX, Class I Division 2; Railway: EN 50121-4; Traffic Control: NEMA TS2; Vibration: IEC 60068-2-6; Shock: IEC 60068-2-27; Freefall: IEC 60068-2-31; Maritime: ABS, LR, NK, DNV; IP30;Telcordia (Bellcore), GB |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Weight | 275 g (0.61 lb) |
| Switch and Hub : Standards and Protocols | |
| Protocols and work standards | - |
| Protocols and management standards | - |
| Switch and Hub : Package Checklist | |
| Hardware installation guide | Yes |
| Power adapter | No |
| Power cable | No |