MOXA EDS-408A-PN INTRODUCTION
The Moxa EDS-408A-PN managed Ethernet switch is an
industrial-grade solution specifically designed to meet the demanding needs of
various industries, including marine, oil and gas, railway transportation,
water and wastewater, factory automation, and road transportation. The Moxa EDS-408A series features superior reliability, redundancy, and security
features based on IEC 62443 standards to ensure the highest level of network
security and resilience. The Moxa layer 2 managed Ethernet switch supports RSTP,
STP, Turbo Chain, and Turbo Ring v1/v2 to facilitate flawless network
redundancy and continuous operations in mission-critical applications. Also,
the web-based management of the Turbo Ring or DIP switch control simplifies the
deployment of the EDS-408A-PN. Implement the Moxa EDS-408A-PN for reliable and
secure data transmission and easy maintenance.
Reliable Managed Ethernet Switch with Enhanced Connectivity
The EDS 408A PN is an Entry-level managed Ethernet switch
that features eight Ethernet 10/100BaseT(X) ports (RJ45 connector) with
auto-negotiation speed, full and half-duplex modes, and auto MDI/MDI-X
connection. The Moxa EDS 408A PN is PROFINET enabled and easy to install and
manage. Among the main reasons why the Moxa EDS 408A-PN switch is considered a
valuable Moxa switch for demanding environments is its industrial-grade
durability and connectivity.
Rugged Design with a Wide Temperature Range
The Moxa EDS-408A-PN managed switch comes in a durable metal
housing built to withstand diverse weather conditions. With DIN-rail mounting
and wall-mounting installation options, this industrial switch offers
straightforward deployment. This IP30-rated Moxa EDS-408A-PN switch supports an
operating temperature range of -10 to 60°C (14 to 140°F) and a weight of 650
grams (1.44 lbs). The Moxa-managed Ethernet switch provides durable and
reliable connectivity to operate well in diverse and challenging operational
environments.
Reliable Input Voltage with Redundant Dual Inputs
The Moxa EDS-408A-PN Ethernet switch features redundant dual
inputs connected through a removable 6-contact terminal block to deliver
flexible power configurations. With a redundant dual Input voltage range of
12/24/48 VDC, the EDS 408A PN switch facilitates reliable connectivity even
during voltage fluctuations. This Moxa Ethernet switch also supports overload
current protection and reverse polarity protection to reinforce reliability
under varying power conditions. Refer to the Moxa EDS-408A-PN datasheet for
more information.
As an Authorized Distributor of MOXA, Manufacturers Automation Inc. (ManuAuto) offers a wide variety of Industrial Automation and Communication products across North America, including Canada (Ontario, Toronto) and the US. Buy MOXA EDS-408A-PN Managed Ethernet Switch online at a competitive price, with on-time delivery and fast shipping services. Our certified engineers are always available to support you.
You can also find the EDS-408A-PN-T, EDS-408A, EDS-408A-SS-SC, EDS-408A-MM-ST, and EDS-408A-3M-SC models in the MOXA EDS-408A Series.
MOXA EDS-408A-PN CERTIFICATIONS
The Moxa EDS-408A-PN managed Ethernet switch complies with industrial standards, including safety,
free-fall, and shock certifications. Additionally, the switch also provides FCC
and vibration certifications to verify the device's safety in challenging environments,
especially where substantial interference and physical stress are present. The
EN 50121-4 certification proves that the device is safe to use for railway and
transportation applications. NEMA TS2 certification ensures reliable operation
under severe temperatures, and maritime and Hazardous Locations certification
guarantees that the device is safe for offshore and onshore applications that
demand strict safety standards. The Moxa industrial network infrastructure
strives to bring maximum efficiency in high-risk environments.

| Switch and Hub : Interface | |
| Number of ports | 8 Ports |
| 10/100Mb RJ45 (Megabit) Ports | Yes : 8 Ports |
| 10/100/1000Mb RJ45 (Gigabit) Ports | No |
| 100Mb Fiber optic multi mode (Megabit) Ports | No |
| 100Mb Fiber optic single mode (Megabit) Ports | No |
| 100Mb SFP Fiber optic (Megabit) Ports | No |
| 1000Mb SFP Fiber optic (Gigabit) Ports | No |
| 10/100Mb (Megabit) POE Ports | No |
| 10/100/1000Mb (Gigabit) POE Ports | No |
| Other ports | Yes : 1 x RS-232 Console Port, 1 x Alarm Contact Channel |
| Switch and Hub : Features and Capabilities | |
| Backup | Yes : ABC-01 |
| Switch and Hub : LED Indicators | |
| LED Per Port | Yes |
| Switch and Hub : Power Requirements | |
| Input Voltage | 12/24/48 VDC |
| Input Current | 0.61 @ 12 VDC, 0.3 @ 24 VDC, 0.16 @ 48 VDC |
| Operating Voltage | 9.6 to 60 VDC |
| Power Input Plugin ( Redundant ) | Yes |
| Power Consumption | - |
| Switch and Hub : General | |
| Fan / Fanless | Fanless |
| MTBF | 1,339,439 hrs |
| Switch and Hub : Switch Specifications | |
| Most forwarding speed | - |
| Network working layers | Layer 2 |
| Switch type | Managed |
| Port Aggregation | No |
| Switch and Hub : Physical Characteristics | |
| Dimensions | 53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in) |
| Housing | Metal |
| Installation | DIN-rail mounting, Wall mounting (with optional kit) |
| Operating Temperature | -10 to 60°C (14 to 140°F) |
| Operation Humidity | 5 to 95% (non-condensing) |
| Standards and Certifications | Safety: UL 508, UL 6095-01. EN 62368-1, EMC: EN 55032/35, EMI: CISPR 32, FCC Part 15B Class A; EMS: IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m, IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV, IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV, IEC 61000-4-6 CS: 10 V, IEC 61000-4-8 PFMF; Hazardous Locations: ATEX, Class I Division 2, IECEx; Railway: EN 50121-4; Traffic Control: NEMA TS2; Vibration: IEC 60068-2-6, Shock: IEC 60068-2-27; Freefall: IEC 60068-2-31; Maritime: ABS; IP30; Telcordia (Bellcore), GB |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Weight | 650 g (1.44 lb) |
| Switch and Hub : Standards and Protocols | |
| Protocols and work standards | EtherNet/IP, Modbus TCP, PROFINET IO Device (Slave), RSTP, STP, Turbo Chain, Turbo Ring v1/v2 |
| Protocols and management standards | Back Pressure Flow Control, BOOTP, DHCP Option 66/67/82, DHCP Server/Client, Flow control, IPv4/IPv6, LLDP, Port Mirror, RARP, RMON, SMTP, SNMP Inform, SNMPv1/v2c/v3, Syslog, Telnet, TFTP; 802.1Q VLAN, GMRP, GVRP, IGMP v1/v2, Port-based VLAN |
| Switch and Hub : Package Checklist | |
| Hardware installation guide | Yes |
| Power adapter | No |
| Power cable | No |