MOXA MGate MB3170 Industrial Ethernet Gateway
- Model: MGate MB3170
The Moxa MGate MB3170 Connects Legacy Modbus Devices to Modern Ethernet Networks
Legacy equipment doesn't have to sit outside your network. The Moxa MGate MB3170 industrial Ethernet gateway connects a serial device to modern Ethernet systems, acting as a dependable Modbus TCP gateway between the two.
This MGate MB3170 gateway is trusted across marine, oil and gas, and factory automation applications, where real-time monitoring and precise control matter.
How the MGate MB3170 Bridges Legacy and Ethernet Networks
At its core, the MGate MB3170 works as a Modbus TCP to Modbus RTU converter. It functions as a Modbus protocol gateway, translating Modbus RTU/ASCII signals into Modbus TCP so older devices can join a modern network. As a serial-to-Ethernet gateway, it solves a common headache: legacy device integration, keeping older Modbus equipment operational without forcing a full hardware replacement.
This Modbus communication gateway handles protocol conversion automatically. Auto Device Routing maps the serial device to the Ethernet network without manual configuration, saving setup time and reducing the risk of configuration errors.
On the connectivity side, the gateway speaks the protocols that keep serial and Ethernet devices talking to each other. Modbus TCP Client/Server (Master/Slave) and Modbus RTU/ASCII Master/Slave modes cover both sides of the conversion. It includes 1 serial port with RS-232/422/485 support, runs on 12 to 48 VDC input power, and connects to up to 32 Modbus TCP clients/servers. SNMPv1/v2c/v3, HTTPS/TLS 1.2, and standard Modbus function codes round out its communication options. For facilities that need fiber connectivity or a wider temperature range, those variants are available elsewhere in the MGate MB3170 series.
Key Specs at a Glance
|
Feature |
Detail |
|
Serial Port |
1 x RS-232/422/485 (DB9 male + terminal block) |
|
Ethernet Ports |
2 x 10/100BaseT(X) (RJ45) |
|
Power Input |
12 to 48 VDC, dual input |
|
Operating Temperature |
0 to 60°C |
|
Modbus Clients/Servers |
Up to 32 |
|
MTBF |
Approx. 1.66 million hours (Telcordia SR332) |
Certifications Behind the MGate MB3170
- ATEX / IECEx / Class I Division 2 Certified: Safe for hazardous, explosive locations across North America and internationally
- UL 508 / UL 60950-1: Confirms safety compliance for industrial equipment
- DNV Maritime Certification: Suited for marine applications
- CE / FCC Part 15B Class A: Meets international EMC standards
Ready to Order the MGate MB3170?
The MGate MB3170 is available across Canada and North America, built to bring your existing Modbus devices onto a modern Ethernet network without a full equipment overhaul. Before you order, our team can confirm it's the right fit for your specific serial devices and network setup.
Common Questions About the MGate MB3170
1. What is the MGate MB3170?
It's a 1-port advanced Modbus gateway that converts Modbus RTU/ASCII to Modbus TCP, connecting a serial device to an Ethernet network.
2. How does the MGate MB3170 work?
It translates Modbus RTU/ASCII signals into Modbus TCP format, allowing a serial device to communicate over Ethernet with PLCs, SCADA platforms, and other network-based systems.
3. What protocols and serial standards does the MGate MB3170 support?
It supports Modbus TCP Client/Server and Modbus RTU/ASCII Master/Slave modes, with RS-232, RS-422, and RS-485 serial connections. SNMP and HTTPS/TLS 1.2 are included for secure network management.
4. Can the MGate MB3170 connect PLCs and multiple RTU devices?
Yes. It connects a serial PLC or other Modbus RTU/ASCII device to Ethernet-based SCADA and control systems, and supports up to 32 Modbus TCP clients/servers.
5. What is the default IP address of the MGate MB3170?
The default IP address is 192.168.127.254, with default login admin / moxa. Moxa recommends changing the default password during setup.
6. How do I configure and set up the MGate MB3170?
Configuration is done through Auto Device Routing or the embedded web console, using the configuration utilities, wiring diagram, and firmware Moxa provides through its official support resources.
7. Where is the MGate MB3170 used?
Common applications include marine, oil and gas, and factory automation, wherever a serial Modbus device needs to join an Ethernet-based control system.
8. Does the MGate MB3170 support industrial temperatures?
Yes, it operates reliably from 0 to 60°C. A wide-temperature variant (-40 to 75°C) is also available in the broader MGate MB3170 series.
9. Is the MGate MB3170 available in Canada, and does ManuAuto offer support?
Yes. The MGate MB3170 is available through our distribution network across Canada and North America, and our team provides technical support and product guidance for Moxa gateways.
10. What warranty does the Moxa MGate MB3170 have?
The MGate MB3170 carries Moxa's standard 5-year warranty.
| Industrial Gateway : Interface | |
| 10/100Mb RJ45 (Megabit) Ports | Yes : 2 Ports (1 IP, Ethernet cascade, Auto MDI/MDI-X connection) |
| Magnetic Isolation Protection | 1.5 kV (built-in) |
| Other ports | No |
| Protocols | Ethernet: Modbus TCP Client (Master), Modbus TCP Server (Slave), Serial: Modbus RTU/ASCII Master, Modbus RTU/ASCII Slave |
| Industrial Gateway : Serial port specifications | |
| Console Port | No |
| Number of Ports | 1 Port |
| Serial Standards | RS-232/422/485 |
| Connectors | DB9 male for RS-232, Terminal block for RS-422/485 |
| Isolation | No |
| Industrial Gateway : Serial Communication Parameters | |
| Data Bits | 7, 8 |
| Stop Bits | 1, 2 |
| Parity | None, Even, Odd, Space, Mark |
| Flow Control | DTR/DSR, RTS Toggle (RS-232 only), RTS/CTS |
| Baudrate | 50 bps to 921.6 kbps |
| Industrial Gateway : Serial Signals | |
| RS-232 Signals | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
| RS-422 Signals | Tx+, Tx-, Rx+, Rx-, GND |
| RS-485-4w Signals | Tx+, Tx-, Rx+, Rx-, GND |
| RS-485-2w Signals | Data+, Data-, GND |
| Industrial Gateway : General | |
| Management | ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, Telnet, UDP, NTP Client |
| MTBF | 1,662,526 hrs |
| Industrial Gateway : Memory | |
| microSD Slot | No |
| Industrial Gateway : Power Requirements | |
| Input Current | 435 mA @ 12 VDC |
| Input Voltage | 12 to 48 VDC (Redundant dual power inputs) |
| Power Connector | 7-pin terminal block |
| Industrial Gateway : Security | |
| Security | Security Protocols: SNMPv3, HTTPS (TLS 1.2) |
| Authentication | Local database |
| Encryption | HTTPS, AES-128, AES-256, SHA-256 |
| Industrial Gateway : Physical Characteristics | |
| Dimensions | with ears: 29 x 89.2 x 124.5 mm (1.14 x 3.51 x 4.90 in), without ears: 29 x 89.2 x 118.5 mm (1.14 x 3.51 x 4.67 in) |
| Standards and Certifications | EMC: EN 55032/35; EMI: CISPR 32, FCC Part 15B Class A; EMS: IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m, IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV, IEC 61000-4-5 Surge: Power: 2 kV, IEC 61000-4-6 CS: 10 V, IEC 61000-4-8 PFMF, IEC 61000-4-11; Hazardous Locations: ATEX, Class I Division 2, IECEx; Maritime: DNV; Freefall: IEC 60068-2-32; Shock: IEC 60068-2-27; Vibration: IEC 60068-2-6, IEC 60068-2-64; Safety: UL 60950-1, IEC 60950-1, EN 62368-1, UL 508; IP30; Telcordia SR332 |
| Housing | Plastic |
| Operating Temperature | 0 to 60°C (32 to 140°F) |
| Weight | 360 g (0.79 lb) |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| Installation | DIN-rail mounting |